EasyManuals Logo

Daikin 2MXS-N Series User Manual

Daikin 2MXS-N Series
661 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #89 background imageLoading...
Page #89 background image
Wiring Diagrams EDUS121503A
84 Multi-Split Type Air Conditioners 2/3/4MXS-N Series
FTXS15/18/24LVJU
FDXS09/12LVJU, CDXS15/18/24LVJU
WIRING DIAGRAM
1
FU1
X1M
PCB1PCB3
S46S49
2
H1
F1U
BLK 11
BLK 1
LED1
3
~
BLK
3.15A
H1P
WHT
OUTDOOR
2
BLK
C102
V1
BLK
LED2
RED 3
-
H2
MR10
BLK
GRN
H2P
BLK
FIELD WIRING.
BLK
LED3
GRN / YLW
C101
BLK
H3
H3P
99BLK
CAUTION
FG
SW1
S21
FU2
S1
F2U
HA
7
RED
RTH1
BZ
3.15A
R1T
4
BLU
S25
BLK
BRN
11
PCB4
BLK
ORG
S36
1 WHT
3
S41S47 S32
BLK
4
M1F
9114132118 7141016 12 6 1521335
BLK
BLK
BLK
BLK
BLK
PNK
PNK
PNK
BLU
BLU
BLU
ORG
ORG
ORG
RED
RED
RED
YLW
YLW
YLW
S48
PCB2
13
INDOOR
R2T
MSWMSWMSW
M1S M3SM2S
BZ
C101, C102
FG
F1U, F2U
H1P~H3P
MR10
M1F
M1S~M3S
PCB1~PCB4
R1T, R2T
S1~S49
SW1
V1
X1M
: BUZZER
: CAPACITOR
: FRAME GROUND
: FUSE
: PILOT LAMP
: MAGNETIC RELAY
: FAN MOTOR
: SWING MOTOR
: PRINTED CIRCUIT BOARD
: THERMISTOR
: CONNECTOR
: OPERATION SWITCH
: VARISTOR
: TERMINAL STRIP
: PROTECTIVE GROUND
INTELLIGENT EYE
SENSOR
WIRELESS
REMOTE
CONTROLLER
SIGNAL
RECEIVER
MS
3
~
TRANSMISSION
CIRCUIT
NOTE THAT OPERATION WILL RESTART
AUTOMATICALLY IF THE MAIN POWER SUPPLY
IS TURNED OFF AND THEN BACK ON AGAIN.
C: 3D060942R
X1M
A1P
11BLK
A2P
H1
2
WHT 2
F1U
3
V1TR
RED 3
OUTDOOR
3.15A
LED LED
LED
S1
S26
GRN
H2
11
FIELD WIRING.
H3PH2PH1P
GRN/YLW
TERMINAL FOR
CENTRALIZED CONTROL
H3
CAUTION
()
GND
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
THE MAIN POWER SUPPLY IS
TURNED OFF AND THEN BACK
ON AGAIN.
631
S21
S1W
S1
SIGNAL
RECEIVER
RED BLK
S7
1010
1GRY
YLW
RTH1
S32
2121
3
C1
WHT
BRNBRN
t°
M
t°
1~
Q1M
PPL
R1T
INDOOR
130°C
BLU
R2T
M1F
: PROTECTIVE GROUND
C1 : CAPACITOR (M1F)
F1U : FUSE
WIRELESS
REMOTE
CONTROLLER
TRANSMISSION
CIRCUIT
: PILOT LAMP H1P~H3P
: FAN MOTORM1F
: PRINTED CIRCUIT BOARDA1P~A2P
: THERMAL PROTECTOR (FOR MOTOR)Q1M
: THERMISTORR1T~R2T
S1~S32, RTH1 : CONNECTOR
: OPERATION SWITCHS1W
: TRIACV1TR
: TERMINAL BLOCKX1M
C: 3D073998B

Table of Contents

Other manuals for Daikin 2MXS-N Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin 2MXS-N Series and is the answer not in the manual?

Daikin 2MXS-N Series Specifications

General IconGeneral
BrandDaikin
Model2MXS-N Series
CategoryHeat Pump
LanguageEnglish

Related product manuals