24
Handling
Useful
Functions
Timer Operation
With the “ON” timer, the Oil Cooling Unit can be started after elapse of a desired time.
This mode can be used to warm up the main machine.
The operation start time setting range is 0 to 999 hours (in one hour steps).
While the timer mode is selected, keep the main power supply ON.
The value indicated on the control panel will be decremented from a preset value at one-hour intervals.
To cancel the timer mode, set the timer at “0”.
The timer setting is active only once. To use the timer again, you must set up the timer again.
Operating procedure
Go to the timer mode with the key.
See “Mode changing operation on page .
The “TIMER
SET” lamp on the operation mode indicator lights.
“0” blinks on the data display.
1. Select the timer mode.
Change the value on the data display to a desired value with the
or key.
The unit of set value is “h” (hour).
2. Specify an operation start time.
Press the key to register the timer setting.
When the timer is activated, the Oil Cooling Unit is halted.
The value on the data display blinks.
The “TIMER” lamp (red LED) blinks.
Keep the main power supply ON.
3. Set up the timer.
With the built-in heater model (–H), the electric heater heats up oil to a preset temperature during main machine warm-up in
winter. Combining this function with timer operation enables more effective warm-up.
Heater ON: When inlet oil temperature is at least 0.5˚C lower than preset temperature
Heater OFF: When inlet oil temperature is equal to, or higher than preset temperature
Regardless of the operation mode, the Oil Cooling Unit turns ON/OFF the heater by detecting the inlet oil
temperature.
( Only when the compressor is not in operation)
Note that the heater cannot perform high-precision oil temperature control.
Main machine warm-up
17
Data displayOperation mode
indicator
1 2 2
3
PIM00318A_EN.fm Page 24 Tuesday, October 26, 2010 12:37 PM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin AKZ9 Series and is the answer not in the manual?

Daikin AKZ9 Series Specifications

General IconGeneral
BrandDaikin
ModelAKZ9 Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals