EasyManuals Logo
Home>Danfoss>Water Pump>APP 0.6

Danfoss APP 0.6 User Manual

Danfoss APP 0.6
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
User manual Installation, Operation and Maintenance APP Pumps (APP 1.5-3.5)
7
180R9267 / IOM APP Pumps - v02 / 09.2013
2.1 General information
Dangers that can arise from not following the
instructions:
When the pump or pump unit is managed by
untrained personnel, there is a danger of:
Death or fatal injuries
Costly damages and claims
Electrical
hazard
All electrical installation work must only be
carried out by authorized personnel in
accordance with EN60204-1 and/or local
regulations.
It is recommended to install a lockable circuit
breaker to avoid inadvertent starting and/or
electrical hazard. The lockable circuit breaker
must be used during installation, operation and
maintenance.
It is recommended to place a local safety switch
nearby the pump, enabling service personnel to
cut power for the electric motor.
Protect the motor and other electrical equip-
ment from overloads with suitable equipment.
In case the pump delivered is ATEX certied, the
additional ATEX instruction must also be read.
!
Protective
garments
must be worn
Always wear suitable safety clothing when
handling the pump.
When working near the pump system, safety
shoes, safety glasses, hearing protection and
safety helmet must always be worn.
Under certain operational conditions the surface
of the pump can be above 60°C / 14F. Under
these conditions the pump must be labelled with
a “Danger Hot” sign.
When using an electric motor, the motor must
always be supplied with adequate cooling
ventilation.
When using an electric motor together with a
VFD, the motor must be designed for operation
with a VFD.
VFD operation may increase the temperature
inside the electric motor if the motor is not
designed for VFD operation. This can damage
the motor and cause unintended breakdown.
Before start-up, the settings for all protective
devices, such as sensors/switches and safety
valves must be veried and free ow from safety
valves must be ensured.
All pipe and hose connections must be stress-
free mounted, securely fastened to the pump
and well supported. Improper installation will or
can result in personal injury and/or damage to
the pump.
Use of this manual does not relieve operation
and maintenance personnel of the responsibil-
ity of applying good judgment when operating
and maintaining the pump and its compo-
nents.
2.2 Preferred system design
Danfoss recommends to build systems with a
high degree of safety. Danfoss preferred system
design and P&ID are found in appendix 1, Data
sheet, and appendix 2, Instruction.
2. Safety
1.3 Manufacturer and customer service
address
Danfoss A/S
Danfoss High Pressure Pumps
RO Solutions
Nordborgvej 81, D25
DK-6430 Nordborg
Denmark
Telephone: +45 7488 4024
Fax: +45 7445 3831
Email: ro-solutions@danfoss.com
Homepage: www.ro-solutions.com
Your local Danfoss pump distributor can be
found on our homepage.
Data sheets and instructions on all accessories
are available on www.ro-solutions.danfoss.com
EC Declaration of Conformity can be found on
page 5.

Table of Contents

Other manuals for Danfoss APP 0.6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss APP 0.6 and is the answer not in the manual?

Danfoss APP 0.6 Specifications

General IconGeneral
BrandDanfoss
ModelAPP 0.6
CategoryWater Pump
LanguageEnglish

Related product manuals