User manual Installation, Operation and Maintenance APP Pumps (APP 1.5-3.5)
8
180R9267 / IOM APP Pumps - v02 / 09.2013
3.1 Approved applications and operational
limits for the pumps
The pump and the pump units are designed for
the use in a Sea Water Reverse Osmosis (SWRO)
or Brackish Water Reverse Osmosis (BWRO)
systems and Brackish Water Reverse Osmosis
(BWRO) system.
The APP pumps must not be used for other
purposes than those recommended and
specied without rst consulting your local
pump distributor.
Use of the pump in other applications not
suitable for the pump unit can cause damages
to the pump unit, with risk of personal injury.
For system integration of the pump, please see
appendix 1, Data sheet and appendix 2,
Instruction.
3. Technical data
3.2 Application range
See appendix 1, Data sheet.
3.3 Electric motor data
See recommended motor in appendix 1, Data
sheet or appendix 3, IOM for motors. The motors
mentioned are the most common used motors
by Danfoss High Pressure Pumps.
3.4 Noise and vibration
Noise level for a pump unit with a ”standard”
motor measured according to EN ISO 3744: 2010,
see appendix 1, Data sheet. Possibilities to
reduce noise and vibration are described in the
same Data sheet.
3.5 Dimension drawings
Dimensions of the dierent pumps can be found
in appendix 1, Data sheet.
3.6 Space requirement
When doing service or replacing the complete
pump unit, it is recommended to have sucient
space available around the pump in order to
ensure easy access. Sucient space means at
least 1 meter/40 inches around the pump. When
working with high pressures, it is important to
have the right space available around the pump
as stated in the safety requirements.
It is always the system builders´ responsibility
that the system design does not cause any kind
of hazard and is adapted to local regulations and
standards.
Proper installation, proper start up and shut-
down devices as well as high-pressure protection
equipment is essential.
2.3 Commissioning and servicing the unit
It is recommended that commissioning and
servicing are carried out by a minimum of two
people, where one is acting as a supervisor.
2.4 Adhere to the following important
points
Before using the pump/pump unit it is very
important to read and understand this user
manual.
Do not try to lift the pump unit manually;
most of the pumps weigh more than
20 kilos, see specic weight for the pump
in the appendix 1, Data sheet.
Always bleed the pump prior to initial
start-up.
Do not mount the pump without the bell
housing and a exible coupling.
Do not try to start the unit before the
system components are mounted, bleeded
and adjusted.
Flush the system throughly before
connecting the pump or pump unit.
Check rotation direction of the motor
before mounting the pump.
2.5 In case of doubt
Please contact Danfoss A/S in case of doubt.
Contact information is listed in section 1.3,
Manufacturer and customer service address.

Table of Contents

Other manuals for Danfoss APP 0.6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss APP 0.6 and is the answer not in the manual?

Danfoss APP 0.6 Specifications

General IconGeneral
BrandDanfoss
ModelAPP 0.6
CategoryWater Pump
LanguageEnglish

Related product manuals