F) Slowly unscrew and remove the bolts and
gaskets from the inlet/outlet hoses or
pipes, be careful about jets of water. Be
aware that the system can be pressurized.
G) Attach the lifting equipment to the pump
unit. For instructions on lifting the
complete pump unit, see chapter 4, Arrival
inspection, transportation, handling, lifting
and storage.
H) For the small pumps, unscrew the bolts
holding the pump to the bell housing and
for the bigger pumps, unscrew the bolts/
nuts from the pump and bell housing to
the motor and afterwards unscrew the
bolts/nuts holding the pump and bell
housing.
I) Carefully pull the pump out of the bell
housing by using lifting equipment, if
necessary.
J) Hold the pump in dierent positions above
a drip tray; this should allow most of the
water trapped in the pump to drain. Clean
and dry the pump surface and plug the
bleeding and draining plugs.
K) Move the pump to a clean and safe location
where the pump can be inspected/
serviced.
7.4 Disassembling and assembling the
pump unit
A) Remove all connections from the pump.
B) Disassemble the pump according to the
Disassembling and Assembling Instruction
(available at
www. danfoss.high-pressurepumps.com).
Clean all the parts and surfaces with a uid
compatible with the materials found in the
pump. Wipe the parts clean and dry with a
lint-free clothing.
C) Inspect all parts including shaft seal and if
necessary, replace them; see appendix 4,
Parts list.
D) If the pump is going to be returned to
Danfoss for repair or a warranty claim, it is
important to contact Danfoss in order to
receive a return number and a form to ll
out with product information. A copy of the
form together with contact information
and reason for returning should be sent to
the email address on the form. The same
documents should be attached to the
shipment.
Returns without a return number will be
rejected !!!
7.5 Assembling the pump unit
Assemble the pump according to the Disassem-
bling and Assembling Instruction (available at
www. danfoss.high-pressurepumps.com).
7.6 Procedure for mounting the pump back
onto electric motor
Mount the exible coupling and bell housing
according to appendix 2, Instruction.
7.7 Getting the pump unit back into
operation
Find instructions of how to put the pump unit
back into operation in chapter 4, Arrival inspec-
tion, transportation, handling, lifting and storage
and Installation and commissioning, chapter 5.
7.8 Storage of the pump
If the pump has to be shut down for a longer
period, instructions can be found in appendix 2,
Instruction.

Table of Contents

Other manuals for Danfoss PAH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PAH Series and is the answer not in the manual?

Danfoss PAH Series Specifications

General IconGeneral
BrandDanfoss
ModelPAH Series
CategoryWater Pump
LanguageEnglish

Related product manuals