Instruction Pump instruction PAH / PAHT 2-12.5
39
© Danfoss | DHS (im) | 2022.07
180R9379 | AQ188686503004en-000801 | PAH 2-12.5
|
3.4 Protection from too high pressures
The pump should be protected against too high
pressure by means of a pressure relief valve or a
bypass/unloading valve placed on the pressure
side.
The valve should be placed as close to the pump
as possible.
The opening characteristics of the valve must not
result in peak pressures higher than 200 bar
(2900 psi).
The valve outlet must not be connected directly
to the pump suction line. It shall be connected
directly to the tank.
PAH / PAHT 2-6.3 PAH / PAHT 10-12.5
P T C P T C
Thread size
G 1⁄4 x 11 G 12 x 15
M6; Allen key
4 mm
G 38 x 15 G 34 X 17
G 1⁄4, NV6
14 deep
Max tighten
torque
25 Nm 25 Nm 5 Nm 25 Nm 25 Nm 15 Nm
3.5 Connections
P: Pressure
T: Tank
C: Bleeding
D: Parallel key
5 x 5 x 20,
DIN 6885
Recommended torque values refer to steel washers containing a rubber sealing element.

Table of Contents

Other manuals for Danfoss PAH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss PAH Series and is the answer not in the manual?

Danfoss PAH Series Specifications

General IconGeneral
BrandDanfoss
ModelPAH Series
CategoryWater Pump
LanguageEnglish

Related product manuals