136 MG.30.A7.02 - VLT
®
is a registered Danfoss trademark
Line 4kV/5Hz/CCC 1kV/2 2kV/12 - -
Motor 2kV/5Hz/CCC - - - -
Control lines 2kV/5Hz/CCC - 2kV/2 * - -
PROFIBUS option 2kV/5Hz/CCC - - - -
Signal interface < 3 m 1kV/5Hz/CCC - - - -
Enclosure - - -
8 kV AD
6 kV CD
10V/m
Basic standard Burst
IEC 1000-4-4
Surge
IEC 1000-4-5
ESD
IEC 1000-4-2
Radiated elec-
tromagn. field
IEC 1000-4-3
Acceptance criterion B B B A
Port connection CM DM CM
Line OK OK OK - -
Motor OK - - - -
Control lines OK - OK - -
PROFIBUS option OK - - - -
Signal interface < 3 m OK - - - -
Enclosure - - - OK OK
Immunity
EMC testresults
Basic standard Burst
IEC 1000-4-4
Surge
IEC 1000-4-5
ESD
IEC 1000-4-2
Radiated elec-
tromagn. field
IEC 1000-4-3
Acceptance criterion B B B A
Port connection CM DM CM
Line OK OK OK - -
Motor OK - - - -
Brake OK - - - -
Control lines OK - OK - -
PROFIBUS option OK - - - -
Signal interface < 3 m OK - - - -
Enclosure - - - OK OK
Line 2kV/5kHz/DCN 2kV/2 4kV/12 - -
Motor 2kV/5kHz/CCC - - - -
Brake 2kV/5kHz/CCC - - - -
Control lines 2kV/5kHz/CCC - 2kV/2 * - -
PROFIBUS option 2kV/5kHz/CCC - - - -
Signal interface < 3 m 1kV/5kHz/CCC - - - -
Enclosure - - -
8 kV AD
6 kV CD
10V/m
VLT
®
3011-3052 380-500V, VLT
®
3006-3022 200V
VLT
®
3060-3250 380-500V, VLT
®
3032-3052 200V
Ω
Ω
Ω
Acceptance criteria according to: IEC 22G/21/CDV, EN50082-2, 175R0740
DM: Differential mode
CM: Common mode
CCC: Capacitive clamp coupling
DCN: Direct coupling network
* Injection on cable shield
** 2,3 x Û
N
: max. testpulse 1250 V peak
Acceptance criteria according to: IEC 22G/21/CDV, EN50082-2, 175R0740
DM: Differential mode
CM: Common mode
CCC: Capacitive clamp coupling
DCN: Direct coupling network
* Injection on cable shield
** 2,3 x Û
N
: max. testpulse 1350 V peak
ΩΩ
Ω
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com