24 MG.30.A7.02 - VLT
®
is a registered Danfoss trademark
Mains supply 3 x 380/400/415 V Technical data
Acc. to international VDE and UL/CSA requirements VLT type 3002 3003 3004 3006 3008 3011 3016 3022 3032 3042 3052
Constant torque (CT):
Output current I
VLT,N
[A] 2.8 4.1 5.6 10.0 13.0 16.0 24.0 32.0 44.0 61.0 73.0
I
VLT,MAX
[A] (60 s) 3.5 6.5 9.0 16.0 20.8 25.6 38.4 51.2 70.4 97.6 117.0
Output S
VLT,N
[kVA] 2.0 2.9 4.0 7.2 9.3 11.5 17.2 23.0 31.6 44.0 52.5
S
VLT,MAX
[kVA] (60 s) 2.5 4.6 6.4 11.5 15.0 18.4 27.6 36.8 50.5 70.2 84.1
Typical shaft output P
VLT,N
[kW] 1.1 1.5 2.2 4.0 5.5 7.5 11.0 15.0 22.0 30.0 37.0
Quadratic torque (VT):
Output current I
VLT,N
[A] 2.8 4.1 5.6 13.0 16.0 24.0 32.0 44.0 61.0 73.0 88.0
Output S
VLT,N
[kVA] 2.0 2.9 4.0 9.3 11.5 17.2 23.0 31.6 44.0 52.5 63.3
Typical shaft output P
VLT,N
[kW] 1.1 1.5 2.2 5.5 7.5 11.0 15.0 22.0 30.0 37.0 45.0
Max. cable cross-section [mm
2
] 2.5 2.5 2.5 2.5 2.5 16.0 16.0 16.0 35.0 35.0 50.0
Max. motor cable length [m] 300, with screened cables: 150 m
Output voltage U
M
[%] 0-100, of mains voltage
Output frequency f
M
[Hz] 0-120 or 0-500; programmable
Rated motor voltage U
M,N
[V] 380/400/415
Rated motor frequency f
M,N
[Hz] 50/60/87/100
Thermal protection during operation
Integrated thermal motor protection (electronic);
thermistor to DIN 44081
Switching on output Unlimited (frequent switching on output may result in fault message)
Ramp times [s] 0.1 - 3600
VLT type 3002 3003 3004 3006 3008 3011 3016 3022 3032 3042 3052
Max. input current const. load I
L,N
[A] 2.8 4.8 7.0 10.0 13.0 13.8 21.8 30.7 41.9 55.6 66.5
quad. load. I
L,N
[A] 2.8 4.8 7.0 13.0 17.0 22.0 31.0 41.5 57.5 66.5 80.0
Max. cable cross-section [mm
2
] 2.5 2.5 2.5 2.5 2.5 16.0 16.0 16.0 35.0 35.0 50.0
Max. pre-fuses [A] 16.0 16.0 16.0 25.0 25.0 50.0 63.0 63.0 80.0 100
1)
125
1)
Supply voltage [V] 3 x 380/400/415 ±10% (VDE 0160)
Supply frequency [Hz] 50/60 Hz
Power factor / cos. ϕ
1
0.9/1.0
Efficiency 0,96 at 100% load
Switching on input times/min. 2
VLT type 3002 3003 3004 3006 3008 3011 3016 3022 3032 3042 3052
Weight (kg)
IP 00 7.4 7.4 7.4 12.0 14.0 - - - - - -
IP 20-----24.0 26.0 32.0 49.0 54.0 54.0
IP 21 8.0 8.0 8.0 13.0 15.0 - - - - - -
IP 54 11.0 11.0 11.0 14.0 15.0 34.0 37.0 48.0 63.0 69.0 69.0
Power loss CT [W] 60 100 130 195 200 270 425 580 880 1390 1875
at max. load VT [W] 60 100 130 280 300 425 580 880 1390 1875 2155
Enclosure VLT type 3002-08: IP 00 / IP 21 / IP 54
VLT type 3011-52: IP 20 / IP 54
Vibration test [g] 0.7
Relative humidity [%] VDE 0160 5.2.1.2.
[°C] -10→ +40 -10→ +45/40 (CT/VT)
Ambient temperature operation at full load
2)
at full load
2)
(to VDE 0160) [°C] -25→ +65/70, -25→ +65/70,
in storage/transport in storage/transport
EMC standards Emission EN 55011, EN 55014, EN 61000-3-2
(See section “EMC test results”) Immunity EN 50082-2, IEC 1000-4-2, IEC 1000-4-3, IEC 1000-4-4,
IEC 1000-4-5, VDE 0160, ENV 50140, ENV 50141
1) Only semi-conductor fuses.
2) In the range -10 to 0°C, the equipment can start and run; however, the display values and certain operating characteristics will not fulfil the
specifications.