Page #136 background image
-
-
-
Parameter 5-12 Terminal 27 Digital Input to [2] Coasting Stop, Inverse.
Parameter 5-02 Terminal 29 Mode to [1] Terminal 29 Mode Output.
Parameter 5-31 Terminal 29 Digital Output to [27] Torque limit & stop.
Connect to relay output 1 (XD2.21). Then set parameter 5-40 Function Relay to [32] Mechanical Brake Control.
+24 V DC
P 5-10 [8]
P 5-12 [2]
P 5-02 [1]
P 5-31 [27]
GND
P 5-40 [0] [32]
Relay 1
-
+
e30bu096.10
XD2.19
XD2.18
XD2.17
XD2.16
XD2.15
XD2.14
XD2.13
XD2.12
XD2.11
XD2.10
XD2.23XD2.21 XD2.22
External
24 V DC
Mechanical brake connection
I
max
0.1 Amp
Start
Illustration 73: Wire Configuration for Torque and Stop Limit
AQ262139143212en-000301 / 130R0879136 | Danfoss A/S © 2021.10
Wiring Configuration Examples
VLT® AutomationDrive FC 302
Operating Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 300 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 300 Series and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 300 Series Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 300 Series
CategoryDC Drives
LanguageEnglish

Related product manuals