NB!
If one of the settings in par. 1-2* is changed, par. 1-30 to par. 1-39, the advanced motor parameters, will return to default setting.
3-02 Minimum Reference
Range: Function:
Application
dependent*
[Application dependant] Enter the Minimum Reference. The Minimum Reference is the lowest value obtainable by summing
all references.
Minimum Reference is active only when par. 3-00
Reference Range
is set to
Min.- Max.
[0].
The Minimum Reference unit matches:
The choice of configuration in par. 1-00
Configuration Mode
Configuration Mode
: for
Speed
closed loop
[1], RPM; for
Torque
[2], Nm.
The unit selected in par. 3-01
Reference/Feedback Unit
.
3-03 Maximum Reference
Range: Function:
Application
dependent*
[Application dependant] Enter the Maximum Reference. The Maximum Reference is the highest value obtainable by summing
all references.
The Maximum Reference unit matches:
The choice of configuration in par. 1-00
Configuration Mode
: for
Speed closed loop
[1],
RPM; for
Torque
[2], Nm.
The unit selected in par. 3-00
Reference Range
.
3-41 Ramp 1 Ramp up Time
Range: Function:
Application
dependent*
[Application dependant] Enter the ramp-up time, i.e. the acceleration time from 0 RPM to the synchronous motor speed n
S
.
Choose a ramp-up time such that the output current does not exceed the current limit in
par. 4-18
Current Limit
during ramping. The value 0.00 corresponds to 0.01 sec. in speed mode.
See ramp-down time in par. 3-42
Ramp 1 Ramp Down Time
.
Par
. 3 41 =
t
acc
s
x
n
s
RPM
ref
RPM
3-42 Ramp 1 Ramp Down Time
Range: Function:
Application
dependent*
[Application dependant] Enter the ramp-down time, i.e. the deceleration time from the synchronous motor speed n
s
to 0
RPM. Choose a ramp-down time such that no over-voltage arises in the inverter due to regenerative
operation of the motor, and such that the generated current does not exceed the current limit set
in par. 4-18
Current Limit
. The value 0.00 corresponds to 0.01 s in speed mode. See ramp-up time
in par. 3-41
Ramp 1 Ramp up Time
.
Par
. 3 42 =
t
dec
s
x
n
s
RPM
ref
RPM
4 How to Programme
VLT
®
AutomationDrive FC 300 Operating
Instructions
48
MG.33.AG.02 - VLT
®
is a registered Danfoss trademark
4

Other manuals for Danfoss VLT AutomationDrive FC 301

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 301 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 301 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 301
CategoryDC Drives
LanguageEnglish

Related product manuals