Page #64 background image
e30bu182.10
U
W
V
1
Illustration 35: Split Shipment Electrical Connections (Top Exit Cabinet)
Motor cables (U/V/W) to motor terminals (U/V/W) in drive cabinet
AQ357954340588en-000201 / 130R088164 | Danfoss A/S © 2020.09
Electrical Installation
VLT® Refrigeration Drive FC 103
Operating Guide

Table of Contents

Questions and Answers:

Danfoss VLT FC 102 N500 Specifications

General IconGeneral
Power Range0.75 kW to 500 kW
Input Voltage380-480 V
Output Voltage0 V to Input Voltage
Communication ProtocolsCANopen
CoolingForced air cooling
Enclosure TypeIP20, IP21
Protection FeaturesOvercurrent, overvoltage, undervoltage, short circuit, overtemperature

Summary

2 Safety

2.2 Qualified Personnel

Specifies the requirements for personnel authorized to install, operate, and maintain the equipment.

2.3 Safety Precautions

Highlights critical warnings about preventing injury and equipment damage.

4 Mechanical Installation

4.6 Installation Requirements

Outlines general requirements for safe and proper drive installation.

4.11 Installing the Enclosed Drive

Covers procedures for installing the drive into its final location, including cable entry and securing.

5 Electrical Installation

5.1 Safety Instructions

Highlights general safety warnings and specific electrical installation hazards.

5.2 EMC-compliant Installation

Provides guidelines for achieving electromagnetic compatibility during installation.

5.3 Wiring Overview for D9h and D10h Enclosed Drives

Presents a basic wiring diagram for D9h and D10h enclosed drive configurations.

5.4 Wiring Overview for E5h and E6h Enclosed Drives

Presents a basic wiring diagram for E5h and E6h enclosed drive configurations.

5.7 Control Compartment Wiring

Covers wiring procedures within the control compartment, including safety and component details.

5.8 Connecting Motor, Mains, and Ground Cables

Provides essential procedures for connecting motor, mains, and ground cables.

5.9 Installing Upstream Fuses

Covers recommendations and ratings for upstream fuse protection.

5.17 Safe Torque Off (STO) Wiring

Refers to separate documentation for detailed Safe Torque Off (STO) wiring instructions.

6 Pre-start Check List

6.1 Pre-start Check List

Provides a comprehensive checklist of items to verify before initial drive startup.

7 Commissioning

7.1 Applying Power to the Drive

Outlines procedures and safety warnings before applying power to the drive.

7.2 Programming the Drive

Details how to program the drive using the LCP and parameters.

7.3 Testing Before System Start-up

Covers essential tests like motor rotation and encoder feedback before operation.

7.4 Starting Up the Drive for the First Time

Recommends the procedure for initial drive startup after setup completion.

7.5 Parameter Settings

Discusses parameter storage, backup, and management for drive configuration.

8 Wiring Configuration Examples

8.1 Application Examples

Introduces common wiring configurations for various applications like AMA, speed, and feedback.

8.1.1 Wiring Configuration for Automatic Motor Adaptation (AMA)

Shows wiring for Automatic Motor Adaptation (AMA) with T27 connected.

8.1.2 Wiring Configuration for Automatic Motor Adaptation (AMA) without T27

Shows wiring for Automatic Motor Adaptation (AMA) without T27.

8.1.3 Wiring Configuration: Speed

Details wiring for analog speed reference using voltage or current inputs.

8.1.4 Wiring Configuration: Feedback

Describes wiring for analog feedback transducers using 2, 3, or 4-wire connections.

9 Maintenance, Diagnostics, and Troubleshooting

9.3 Warnings and Alarms

Introduces the system for warnings and alarms indicating faults and their causes.

9.4 Troubleshooting

Provides a guide to diagnosing and resolving common drive symptoms and issues.

10 Specifications