Mains supply (L1, L2, L3):
Supply voltage FCD 305-335 380-480 V ........................................................ 3 x 380/400/415/440/480 V ±10%
Supply frequency ..................................................................................................................................... 50/60 Hz
Max. imbalance on supply voltage ........................................................................ ± 2.0% of rated supply voltage
Power factor (400 V) / cos.
1
........................................................................................ 0.90 / 1.0 at rated load
Number of connections at supply input L1, L2, L3 ........................................................................... 2 times/min.
Max. short-circuit value fuses ................................................................................................................ 100,000 A
Max. short-circuit value circuit brakers .................................................................................................... 10,000 A
See Special Conditions section in the Design Guide
Outputdata(U,V,W):
Output voltage ............................................................................................................. 0 - 100% of supply voltage
Output frequency .......................................................................................................... 0.2 - 132 Hz, 1 - 1000 Hz
Rated motor voltage, 380-480 V units ..................................................................... 380/400/415/440/460/480 V
Rated motor frequency ............................................................................................................................ 50/60 Hz
Switching on output ................................................................................................................................ Unlimited
Ramp times ................................................................................................................................. 0.02 - 3600 sec.
Torque characteristics:
Starting torque (parameter 101 Torque characteristic = Constant torque) ..................................... 160% in 1 min.
*
Starting torque (parameter 101 Torque characteristics = Variable torque) ..................................... 160% in 1 min.
*
Starting torque (parameter 119 High starting torque ) ................................................................ 180% for 0.5 sec.
*
Overload torque (parameter 101 Torque characteristic = Constant torque) ................................................... 160%
*
Overload torque (parameter 101 Torque characteristic = Variable torque) ..................................................... 160%
*
*Percentage relates to frequency converters nominal current.
Control card, digital inputs:
Number of programmable digital inputs ................................................................................................................ 5
Terminal number ....................................................................................................................... 18, 19, 27, 29, 33
Voltage level ........................................................................................................ 0 - 24 V DC (PNP positive logic)
Voltage level, logic 0 .............................................................................................................................. < 5VDC
Voltage level, logic 1 ............................................................................................................................ > 10 VDC
Maximum voltage on input ....................................................................................................................... 28 V DC
Input resistance, R
i
(terminals 18, 19, 27) ......................................................................................... approx. 4 k
Input resistance, R
i
(terminal 29, 33) ................................................................................................ approx. 2 k
All digital inputs are galvanically isolated from the supply voltage (PELV) and other high-voltage terminals, and can be
functionally separated from other control terminals by opening switch S100. See section entitled Galvanic Isolation.
MG.04.B7.02 - VLT is a registered Danfoss trademark
109

Table of Contents

Other manuals for Danfoss VLT FCD 315

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FCD 315 and is the answer not in the manual?

Danfoss VLT FCD 315 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FCD 315
CategoryDC Drives
LanguageEnglish

Related product manuals