VLT
®
FCD Series
Installation
1. Prepare the adaptor plate for mounting on the motor by
drilling the fixing holes and the hole for the cables.
2. Mount the plate on the motor with the normal terminal
box gasket.
3. Knock out the 4 screw holes for mounting the adaptor
plate (outer holes).
4. Mount the terminal box onto the motor by the 4 sealing
screws and the gasket supplied.
Use the supplied star washers for securing PE
connection according to EN 60204. The screws must
be tightened with 5 Nm.
Universal adaptorplate
Allowed mounting positions
MG.04.B7.02 - VLT is a registered Danfoss trademark