VLT
®
FCM Series
FCM 305-375 for 3 phases, 380-480 V
FCM 305 307 311 315 322 330 340 355 375
Motor output
[HP] 0.75 1.0 1.5 2.0 3.0 4.0 5.0 7.5 10.0
[kW] 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5
Motor torque
2pole[Nm]
1)
1.8 2.4 3.5 4.8 7.0 9.5 12.6 17.5 24.0
4pole[Nm]
2)
3.5 4.8 7.0 9.6 14.0 19.1 25.4 35.0 48.0
Frame
size [mm] 80 80 90 90 100 100 112 132 132
Weight [kg] 11 13 17 20 26 28 37 56 61
Input current [A]
380 V
2 p 1.5 1.8 2.3 3.4 4.5 5.0 8.0 12.0 15.0
4 p 1.4 1.7 2.5 3.3 4.7 6.4 8.0 11.0 15.5
480 V
2 p 1.2 1.4 1.8 2.7 3.6 4.0 6.3 9.5 11.9
4 p 1.1 1.3 2.0 2.6 3.7 5.1 6.3 8.7 12.3
Efficiency at
nom. speed
(4 pole) % 66 71 74 80 80 81 80 84 84
Efficiency at
nom. speed
(2 pole) % 61 64 76 75 76 85 82 83 91
Power terminals
[AWG] 10101010101010 6 6
[mm2] 4 4 4 4 4 4 4 10 10
Gland sizes 3xM20x1.5 3xM20x1.5 3xM20x1.5 3xM20x1.5 3xM20x1.5 3xM20x1.5 3xM20x1.5 1xM25x1.5/
2xM20x1.5
1xM25x1.5/
2xM20x1.5
Max. prefuse
UL
3)
[A] 1010101010 15152525
IEC
3)
[A] 2525252525 25252525
1)
At 400 V 3000 r/min
2)
At 400 V 1500 r/min
3)
Type gG prefuses must be used. If you want to maintain UL/cUL you must use prefuses of the type Bussmann KTS-R 500 V or Ferraz
Shawmut, ATMR Class C (max. 30A). The fuses must be placed for protection in a circuit that is capable of supplying a maximum of
100,000 amps RMS (symmetrical), 500 V maximum.
General technical data
Mains supply, TT, TN and IT* (L1, L2, L3):
- Supply voltage 380-480 V units .............................................................. 3 x 380/400/415/440/460/480 V ±10%
- Supply frequency ................................................................................................................................... 50/60 Hz
- Max. imbalance of supply voltage ............................................................................ ±2% of
rated supply voltage
- Power factor / cos φ .................................................................................................... max. 0.9/1.0 at rated load
- No. of switching operations on supply input L1, L2, L3 ....................................................... approx. 1 time/2 min
*) Not valid for RFI class 1B units
Torque characteristics:
- Starting torque/overload torque ................................................................................................... 160 % fo
r1min
- Continuous torque ................................................................................................................................ see above
Control card, digital/pulse inputs:
- Number of programmable digital inputs .............................................................................................................. 4
MG.03.H3.02 - VLT is a registered Danfoss trademark
10

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FCM 315 and is the answer not in the manual?

Danfoss VLT FCM 315 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FCM 315
CategoryDC Drives
LanguageEnglish

Related product manuals