[1] Protection Value Port 2 (*Off – 20%)
12-95 Broadcast Storm Filter
Option: Function:
Applies to par. 12-94; if the Broadcast Storm Protection should also include Multicast telegrams.
[0] Broadcast only
[1] Broadcast & Multicast
12-98 Interface Counters
Option: Function:
Read only. Advanced Interface counters, from build-in switch, can be used for low-level trouble-
shooting, The parameter shows a sum of port 1 + port 2.
[0] In Octets
[1] In Unicast Packets
[2] In Non-Unicast Packets
[3] In Discards
[4] In Errors
[5] In Unknown Protocols
[6] Out Octets
[7] Out Unicast Packets
[8] Out Non-Unicast Packets
[9] Out Discards
[10] Out Errors
12-99 Media Counters
Option: Function:
Read only. Advanced Interface counters, from build-in switch, can be used for low-level trouble-
shooting, The parameter shows a sum of port 1 + port 2.
[0] Alignment Errors
[1] FCS Errors
[2] Single Collisions
[3] Multiple Collisions
[4] SQE Test Errors
[5] Deferred Errors
[6] Late Collisions
[7] Excessive Collisions
[8] MAC Transmit Errors
[9] Carrier Sense Errors
[10] Frame Too Long
[11] MAC Receive Errors
MCA 121 EtherNet/IP 6 Parameters
MG.90.J2.02 - VLT
®
is a registered Danfoss trademark
41
6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT MCA 121 EtherNet/IP and is the answer not in the manual?

Danfoss VLT MCA 121 EtherNet/IP Specifications

General IconGeneral
BrandDanfoss
ModelVLT MCA 121 EtherNet/IP
CategoryControl Unit
LanguageEnglish

Related product manuals