16-9* Diagnosis Readouts
16-90 Alarm Word
0-0XFFFFFFFF
16-92 Warning Word
0-0XFFFFFFFF
16-94 Ext. Status Word
0-0XFFFFFFFF
18-** Extended Motor Data
18-8* Motor Resistors
18-80 Stator Resistance (High
resolution)
0.000-99.990 ohm *0.000 ohm
18-81 Stator Leakage Reactance
(High resolution)
0.000-99.990 ohm *0.000 ohm
Table 5.5
5.1.1 Conversion Index
The various attributes of each parameter are displayed in
the section Factory Settings. Parameter values are
transferred as whole numbers only. Conversion factors are
therefore used to transfer decimals according to Table 5.6.
Example:
1-24 Motor Current has a conversion index of -2 (i.e.
conversion factor of 0.01 according to Table 5.6). To set the
parameter to 2.25 A, transfer the value 225 via Modbus.
The Conversion Factor of 0.01 means that the value
transferred is multiplied by 0.01 in the frequency converter.
The vale 225 transferred on the bus is thus perceived as
2.25 A in the frequency converter.
Conversion index Conversion factor
2 10
1 100
0 1
-1 0.1
-2 0.01
-3 0.001
-4 0.0001
-5 0.00001
Table 5.6 Conversion Table
5.1.2 Change during operation
“TRUE” means that the parameter can be changed while
the frequency converter is in operation and “FALSE” means
that the frequency converter must be stopped before a
change can be made.
5.1.3 2-Set-up
“All set-up”: The parameter can be set individually in each
of the two set-ups, i.e. one single parameter can have two
different data values.
”1 set-up”: Data value will be the same in both set-ups.
5.1.4 Type
Data Type Description Type
2 Integer 8 Int8
3 Integer 16 Int16
4 Integer 32 Int32
5 Unsigned 8 Uint8
6 Unsigned 16 Uint16
7 Unsigned 32 Uint32
9 Visible string VisibleString
Table 5.7