1 [OK]: The rst parameter in the group is shown.
2
Press [
▼
] repeatedly to move down to the parameter.
3 Press [OK] to start editing.
4
[►]: First digit ashing (can be edited).
5
[►]: Second digit ashing (can be edited).
6
[►]: Third digit ashing (can be edited).
7
[
▼
]: Decreases the parameter value, the decimal point
changes automatically.
8
[
▲
]: Increases the parameter value.
9 [Back]: Cancel changes, return to 2.
[OK]: Accept changes, return to 2.
10
[
▲
][
▼
]: Select parameter within the group.
11 [Back]: Removes the value and shows the parameter group.
12
[
▲
][
▼
]: Select group.
Table 5.5 Changing Values in Continuous Parameters
For enumerated parameters, the interaction is similar but
the parameter value is shown in brackets because of the
digits limitation (four large digits) on LCP, and the enum
can be greater than 99. When the enum value is greater
than 99, the LCP can only show the
rst part of the
bracket.
130BC447.11
Setup 1
Setup 1
Setup 1
1
2
3
4
5
6
OK
OK
Back
7
OK
Back
Figure 5.6 Main Menu Interactions - Enumerated Parameters
1 [OK]: The rst parameter in the group is shown.
2 Press [OK] to start editing.
3
[
▲
][
▼
]: Change parameter value (ashing).
4 Press [Back] to cancel changes or [OK] to accept changes
(return to screen 2).
5
[
▲
][
▼
]: Select a parameter within the group.
6 [Back]: Removes the value and shows the parameter group.
7
[
▲
][
▼
]: Select a group.
Table 5.6 Changing Values in Enumerated Parameters
Array parameters function as follows:
130BC448.10
1
2
4
5
6
7
8
9
10
OK
Back
Back
Back
5 x
Setup 1
Setup 1
Setup 1
Setup 1
%
INDEX
%
INDEX
%
INDEX
Setup 1
INDEX
%
OK
OK
OK
Figure 5.7 Main Menu Interactions - Array Parameters
1 [OK]: Shows parameter numbers and the value in the rst
index.
2 [OK]: Index can be selected.
3
[
▲
][
▼
]: Select index.
4 [OK]: Value can be edited.
5
[
▲
][
▼
]: Change parameter value (ashing).
6 [Back]: Cancels changes.
[OK]: Accepts changes.
7 [Back]: Cancels editing index, a new parameter can be
selected.
8
[
▲
][
▼
]: Select parameter within the group.
9 [Back]: Removes parameter index value and shows the
parameter group.
10
[
▲
][
▼
]: Select group.
Table 5.7 Changing Values in Array Parameters
5.3.5 GLCP Layout
The GLCP is divided into four functional groups (see
Figure 5.8).
A. Display area
B. Display menu keys
C. Navigation keys and LEDs
D. Operation keys and reset
Commissioning Instruction Manual
MG07A122 Danfoss A/S © 11/2015 All rights reserved. 25
5 5