130BD598.10
Auto
on
Reset
Hand
on
Off
Status
Quick
Menu
Main
Menu
Alarm
Log
Back
Cancel
Info
OK
Status
1(1)
36.4 kW
Auto Remote Ramping
0.000
On
Alarm
Warn.
A
7.83 A
799 RPM
B
C
D
53.2 %
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18 19 20 21
Figure 5.8 Graphic Local Control Panel (GLCP)
A. Display area
The display area is activated when the frequency converter
receives power from the mains voltage, a DC bus terminal
or an external 24 V DC supply.
The information displayed on the LCP can be customized
for user application. Select options in the Quick Menu
Q3-13 Display Settings.
Display Parameter number Default setting
1 0-20 [1602] Reference [%]
2 0-21 [1614] Motor Current
3 0-22 [1610] Power [kW]
4 0-23 [1613] Frequency
5 0-24 [1502] kWh Counter
Table 5.8 Legend to Figure 5.8, Display Area
B. Display menu keys
Menu keys are used for menu access for parameter set-up,
toggling through status display modes during normal
operation and viewing fault log data.
Key Function
6 Status Shows operational information.
7 Quick
Menu
Allows access to programming parameters
for initial set-up instructions and many
detailed application instructions.
8 Main Menu Allows access to all programming
parameters.
9 Alarm Log Displays a list of current warnings, the last 10
alarms and the maintenance log.
Table 5.9 Legend to Figure 5.8, Display Menu Keys
C. Navigation keys and LEDs
Navigation keys are used for programming functions and
moving the display cursor. The navigation keys also
provide speed control in local operation. There are also
three adjustable frequency drive status indicator lights in
this area.
Key Function
10 Back Reverts to the previous step or list in the
menu structure.
11 Cancel Cancels the last change or command as long
as the display mode has not changed.
12 Info Press for a denition of the function being
displayed.
13 Navigation
Keys
Use the four navigation keys to move
between items in the menu.
14 OK Press to access parameter groups or to
enable a selection.
Table 5.10 Legend to Figure 5.8, Navigation Keys
Indicator Light Function
15 On Green The ON light activates when the
frequency converter receives
power from the mains voltage, a
DC bus terminal or an external 24
V supply.
16 Warn. Yellow When warning conditions are met,
the yellow WARN light turns on
and text appears in the display
area identifying the problem.
17 Alarm Red A fault condition causes the red
alarm light to ash and an alarm
text is displayed.
Table 5.11 Legend to Figure 5.8, Indicator Lights (LEDs)
Commissioning
VLT
®
Midi Drive FC 280
26 Danfoss A/S © 11/2015 All rights reserved. MG07A122
55

Table of Contents

Other manuals for Danfoss VLT Midi Drive FC 280

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT Midi Drive FC 280 and is the answer not in the manual?

Danfoss VLT Midi Drive FC 280 Specifications

General IconGeneral
BrandDanfoss
ModelVLT Midi Drive FC 280
CategoryDC Drives
LanguageEnglish

Related product manuals