76 A-Class
Step
Action Displayed Message Comment
G
Observe the calibration
result.
CALIBRATION COMPLETE
Calibration was
successful.
;
If ‘Warning Low
Backing’ is displayed,
calibration was
successful (for
possible messages
see Section 5.1).
H
Press the ESC Key
repeatedly to exit menu
mode.
CALIBRATION COMPLETE
Followed by...
READY
When calibrating gap or
reflective media, press
and hold the FEED Key
until at least one label is
output.
The printer is now ready
for use.
5.2.2 Advanced Entry
;
Advanced Entry will override all previous calibration settings and should only be
used when Standard Calibration attempts fail. Ensure that the correct SENSOR
TYPE is selected (see Section 4.2.1) before staring this procedure.
Advanced Entry is an alternate calibration method for special-case media types, where
sensor readings are taken using different sampling algorithms and from a list of these
readings the best algorithm is selected for manual entry into the database. Follow the steps
below to perform an Advanced Entry Calibration:
Step
Action Displayed Message Comment
A Turn ON the printer.
CANNOT CALIBRATE
-or-
UNCALIBRATED
Wait briefly for the printer
to initialize.
(continued)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax A-Class A-4310 and is the answer not in the manual?

Datamax A-Class A-4310 Specifications

General IconGeneral
BrandDatamax
ModelA-Class A-4310
CategoryLabel Maker
LanguageEnglish

Related product manuals