Page #50 background image
50 | Virtual Server Networking
www.dell.com | support.dell.com
Discovery
The discovery process starts after you enter the no disable command on the interface
and ends 10 minutes after connectivity is established between the switch and
hypervisor. If no connectivity is established, the switch attempts to connect for three
minutes and then stops. Refer to Connectivity for more details on this process.
After you enable the link between a switch and a hypervisor, the switch uses a
discovery mechanism to learn VMAC and VLAN information from the hypervisor.
The discovery process also starts in the following conditions:
You enter the
shutdown and no shutdown commands on a VSN-enabled port.
The discovery process resumes on the individual port only, not on all enabled
ports.
You enter the
disable and no disable commands in hypervisor configuration
mode for a specified type of hypervisor connection. The discovery process is
resumed on all enabled ports.
An update arrives from a hypervisor. The discovery process resumes on all
VSN-enabled ports.
In order for a switch to learn VLAN information from a hypervisor:
Incoming traffic must be received on the VSN-enabled ports.
There must be at least one VMAC configured on the hypervisor so that the VCAP
table can capture the VMAC entries for each VSN-enabled port.
The following log messages are displayed when the discovery process is interrupted
and when it starts again.
Message 1
Nov 28 11:34:19: %STKUNIT0-M:CP %VSNMGR-5-VSN_DISCOVERY_SUSPENDED:
Hypervisor macs not seen on Te 0/25. Discovery suspended.
Message 2
Nov 28 11:40:36: %STKUNIT0-M:CP %VSNMGR-5-VSN_DISCOVERY_RESUMED: Detected
config change in Hypervisor. Discovery of Hypervisor macs resumed on Te 0/25.
Connectivity
If a network server is not reachable, a log message is displayed and the VSN agent
tries periodically to establish the connection with the hypervisor. The initial log
message is:
Message 3
Xen-Citrix:Connection error for hypervisor testing:LOGIN FAILURE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell FORCE10 Open Automation and is the answer not in the manual?

Dell FORCE10 Open Automation Specifications

General IconGeneral
SeriesFORCE10
ModelOpen Automation
Jumbo Frame SupportYes
Product TypeSwitch
PortsVaries by model
Switching CapacityVaries by model
Forwarding RateVaries by model
MAC Address Table SizeVaries by model
Power SupplyVaries by configuration
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
DimensionsVaries by model
WeightVaries by model