100 Troubleshooting Your System
Troubleshooting the System Battery
Problem
System message indicates a problem with the battery.
System Setup program loses system configuration information.
System date and time do not remain current.
NOTE: If the system is turned off for long periods of time (for weeks or months), the NVRAM may lose its
system configuration information. This situation is caused by a defective battery.
Action
1
Re-enter the time and date through the System Setup program. See "Using the System Setup Program" on
page 31.
2
Turn off the system and disconnect it from the electrical outlet for at least one hour.
3
Reconnect the system to the electrical outlet and turn on the system.
4
Enter the System Setup program.
If the date and time are not correct in the System Setup program, replace the battery. See "System Battery"
on page 86.
If the problem is not resolved by replacing the battery, see "Getting Help" on page 125.
NOTE: Some software may cause the system time to speed up or slow down. If the system seems to operate
normally except for the time kept in the System Setup program, the problem may be caused by software rather
than by a defective battery.
Troubleshooting Power Supplies
Problem
System-status indicators are amber.
Power-supply fault indicators are amber.
Front-panel status LCD indicates a problem with the power supplies.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
Run the appropriate online diagnostics test. See "Using Server Administrator Diagnostics" on page 111.
2
Locate the faulty power supply.

Table of Contents

Other manuals for Dell PowerEdge 1950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge 1950 and is the answer not in the manual?

Dell PowerEdge 1950 Specifications

General IconGeneral
Processor Sockets2
ChipsetIntel 5000X
Memory Slots8 DIMM slots
NetworkDual embedded Broadcom NetXtreme II 5708 Gigabit Ethernet
Form Factor1U Rack
ProcessorIntel Xeon 5100, 5300 series
MemoryUp to 32GB DDR2
StorageSAS or SATA
Drive BaysTwo 3.5" SAS or SATA drives or Four 2.5" SAS or SATA drives
RAID ControllerPERC 5/i, PERC 6/i
Power Supply670W redundant power supply (optional)
Operating System SupportMicrosoft Windows Server, Red Hat Linux, SUSE Linux

Related product manuals