102 Troubleshooting Your System
2
Open the system. See "Opening and Closing the System" on page 46.
CAUTION: The cooling fans are not hot-pluggable. To maintain proper cooling while the system is on, only
replace one fan at a time.
3
Locate the faulty fan indicated by the LCD display or diagnostic software. For the identification number
of each fan, see "Removing and Installing a Cooling Fan" on page 49.
4
Ensure that the faulty fan's power cable is firmly attached to the fan power connector. See "Cooling Fan
Modules" on page 48.
NOTE: Wait 30 seconds for the system to recognize the fan and determine whether it is working properly.
5
If the problem is not resolved, install a new fan. See "Cooling Fan Modules" on page 48.
If the replacement fan is working properly, close the system. See "Opening and Closing the System" on
page 46.
If the replacement fan does not operate, see "Getting Help" on page 125.
Troubleshooting System Memory
Problem
Faulty memory module.
Faulty system board.
Front-panel status LCD indicates a problem with system memory.
Action
CAUTION: Many repairs may only be done by a certified service technician. You should only perform
troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.
1
Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" on page 111.
2
Turn on the system and attached peripherals.
If an error message does not appear, continue to the next step.
If an error message appears, go to step 12.
3
Enter the System Setup program and check the system memory setting. See "Entering the System Setup
Program" on page 31.
If the amount of memory installed matches the system memory setting, go to step 12.
4
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
5
Open the system. See "Opening and Closing the System" on page 46.
6
Remove the memory cooling shroud. See "Removing the Memory Cooling Shroud" on page 52.

Table of Contents

Other manuals for Dell PowerEdge 1950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge 1950 and is the answer not in the manual?

Dell PowerEdge 1950 Specifications

General IconGeneral
Processor Sockets2
ChipsetIntel 5000X
Memory Slots8 DIMM slots
NetworkDual embedded Broadcom NetXtreme II 5708 Gigabit Ethernet
Form Factor1U Rack
ProcessorIntel Xeon 5100, 5300 series
MemoryUp to 32GB DDR2
StorageSAS or SATA
Drive BaysTwo 3.5" SAS or SATA drives or Four 2.5" SAS or SATA drives
RAID ControllerPERC 5/i, PERC 6/i
Power Supply670W redundant power supply (optional)
Operating System SupportMicrosoft Windows Server, Red Hat Linux, SUSE Linux

Related product manuals