94 Installing System Components
Hard Drives
Your system supports up to six 3.5-inch or 2.5-inch SATA or SAS hard drives.
Depending on your chassis, the hard drives are installed internally (see
Figure 3-9) or at the front of the system (see Figure 3-7). Internal hard drives are
connected to the system board. Front-mounted hard drives are connected to a
SAS backplane through hard drive carriers and can be configured as hot-
swappable.
Removing a Drive Blank From the Front Bay
CAUTION: To maintain proper system cooling, all empty hard-drive bays must
have drive blanks installed.
1 Remove the front bezel. See
"Removing the Front Bezel" on page 85.
2 Open the drive blank release handle to release the blank.
3
Slide the drive blank out until it is free of the drive bay.
Installing a Drive Blank in the Front Bay
1 Remove the front bezel. See
"Removing the Front Bezel."
2
Open the handle on the drive blank.
3
Insert the drive blank into the drive bay until the blank is fully seated.
4
Close the handle to lock the blank in place.
Removing a Hot-Swap Hard Drive
CAUTION: To prevent data loss, ensure that your operating system supports hot-
swap drive removal and installation. See the documentation provided with your
operating system for more information.
1 Remove the front bezel. See
"Removing the Front Bezel" on page 85.
2
From the RAID management software, prepare the drive for removal.
Wait
until the hard-drive indicators on the drive carrier signal that the drive
can be removed safely.
See your controller documentation for information
about hot-swap drive removal.
If the drive has been online, the green
activity/
fault indicator will flash as
the drive is powered down. When the drive indicators are off, the drive is
ready for removal.
book.book Page 94 Tuesday, June 9, 2009 4:09 PM

Table of Contents

Other manuals for Dell PowerEdge T410

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge T410 and is the answer not in the manual?

Dell PowerEdge T410 Specifications

General IconGeneral
Tcase77.6 °C
Bus typeQPI
SteppingB1
FSB ParityNo
Processor codeSLBV4
Processor cache12 MB
Processor cores4
Processor modelE5620
System bus rate5.86 GT/s
Processor seriesIntel Xeon 5600 Series
Processor socketSocket B (LGA 1366)
Processor threads8
Processor codenameWestmere EP
Motherboard chipsetIntel® 5500
Number of QPI links2
Processor frequency2.4 GHz
Processor cache typeSmart Cache
Processor lithography32 nm
Processor manufacturerIntel
Processor package size42.5 X 45 mm
Processor front side bus- MHz
Processor boost frequency2.66 GHz
Processor operating modes64-bit
ECC supported by processorYes
Supported instruction setsSSE4.2
Thermal Design Power (TDP)80 W
Number of processors installed1
CPU multiplier (bus/core ratio)18
Physical Address Extension (PAE)40 bit
Memory types supported by processorDDR3 800/1066
Memory channels supported by processorTriple
Memory clock speeds supported by processor800, 1066 MHz
Memory bandwidth supported by processor (max)25.6 GB/s
Maximum internal memory supported by processor288 GB
HDD size3.5 \
Optical drive typeDVD-RW
Total storage capacity250 GB
Maximum storage capacity12 TB
Number of HDDs supported6
Memory slots8x DIMM
Internal memory4 GB
Memory clock speed1066 MHz
Internal memory typeDDR3-SDRAM
Maximum internal memory16 GB
Maximum graphics card memory8 MB
Graphics cardG200eW
Dimensions (W x D x H) (imperial)8.58 x 24.28 x 17.52 \
Networking featuresGigabit Ethernet
PS/2 ports quantity0
USB 2.0 ports quantityUSB 2.0 ports have a data transmission speed of 480 Mbps, and are backwards compatible with USB 1.1 ports. You can connect all kinds of peripheral devices to them.
Number of power supply units-
Compatible operating systemsMicrosoft SQL Server 2008 R2/Windows Small Business Server 2008/Essential Business Server 2008/Server 2008 SP2, x86/x64/Server 2008 R2/HPC Server 2008; Novell SUSE Linux Enterprise Server; Red Hat Enterprise Linux.
Chassis typeTower
Processor ARK ID47925
Intel® Turbo Boost Technology1.0
Weight and Dimensions IconWeight and Dimensions
Depth616.8 mm
Width217.9 mm
Height444.9 mm

Related product manuals