6. Troubleshooting
6-9
6.3 Error Detection Devices
Error Check
Devices
Description Drop Latch
STOP

RUN RUN

STOP
M1067
Program execution error flag
None
Reset
Latch
M1068
Execution error latch flag
None
Latch
Latch
D1067
Algorithm error code
None
Reset
Latch
D1068
Step value of algorithm errors
None
Latch
Latch
Device D1067
Error Code
Description
0E18
BCD conversion error
0E19
Division error (divisor=0)
0E1A
Floating point exceeds the usage range
0E1B
The value of square root is negative
0E1C
Instructions FROM/TO communication error