7.3.6 Italy Self-test
Italy Self-test includes Uac High(UH), Uac Low(UL), Fac High(FH) and Fac
Low(FL). User can choose the selection of Uac High, Uac Low, Fac High, or
Fac Low separately. The final testing result will be shown on the operating
page and saved, user can review the results. If the Italy Self-test failed, this PV
inverter would not operate anymore. Please contact with Delta or your supplier
of this PV inverter.
Figure 7-11 Italy self-test flowchart