9.Technical Data
GENERAL
Enclosure
Operating temperature
Operating Altitude
Powder coated aluminum
-25~60℃, full power up to 40℃
(Please refer to figure 9-1 to 9-6.)
2000m
Relative humidity 0 – 100% non condensing.
Environmental category Outdoor, wet locations
Protection degree IP65 (Electronics)
Pollution degree II
Overvoltage category AC output :III, DC Input :II
Maximum backfeed
current to the array
0
Galvanic isolation NO
Safety class Class I metal enclosure with protective earth
Weight 74kg
Dimensions(W*H*D) 612 × 740 × 278mm
48.5kg
612 × 625 × 278mm
Connectors Weather resistant connectors
DC INPUT (Solar side)
Recommended PV power
Maximum input power
Nominal voltage
Operating voltage
Startup voltage
35kW 58kW
≦
38kW
≦
63kW
1000V 1100V*
Rated power
31.5kW 52.5kW
600Vdc
200Vdc – 1000 Vdc
> 250 Vdc
Start up power
40W
MPP tracker
Parallel inputs: 1 MPP tracker
Separate inputs: 2 MPP trackers
Absolute maximum voltage
RPI M30A RPI M50A
* Inverter stop operating when input voltage large than 1000V.
68