Chapter 5 Parameters_VFD-B Series
Revision 10/2005, BE13, SW V4.08 5-105
09 - 05
Reserved
09 - 06
Reserved
09 - 07
aResponse Delay Time Unit: 0.5
Settings 00 ~ 200 msec Factory Setting: 00

This parameter is the response delay time after AC drive receives communication command as shown in
the following.
RS485 BUS
PC or PLC command
Handling time
of AC drive
Response Delay Time
Response Message of AC Drive
Max.: 6msec
Pr.09-07
* This parameter is only for firmware version 4.01 and higher.