Output Value Description
1 +
0 -
24 V= / 0,3 A
(nominal)
24 V= / 0,5 A (peak)
Accessories power supply. External accessories power supply output.
0
14
24 V= / 30 W max. Flashing light (LAMPH). It is activated both on opening and on closing.
24 V= / 25 W Courtesy light. It is activated for 3 minutes on every opening and closing com-
mand.
BAT B
attery operation. An optional battery kit is available (BATK1). With power supply
on, the batteries are kept charged. Without power supply, the panel is powered
by the batteries until power returns or until battery power falls below the safety
threshold. In this latter case, the control panel goes off.
Attention: to allow recharging, the batteries kit must always be connected to the
control panel. Periodically
, verify the battery effi
ciency.
Note: the operating temperature of the rechargeable batteries is +5°C/+40°C
approximately. To ensure proper battery operation rooms should be air-
conditioned.
0
15 24 V= / 1,2 A max Electric lock. It is avtivated at each opening command given from closed door.
0
15
8,2 Ω / 5 W
12 V / 15 W Electric lock. With
a 12 V electric lock, connect the 8,2 Ω / 5 W resistor. It is
activated at each opening command given from closed door.
1
13
24 V= / 3 W Open door
light (analogic output). Light comes on and only goes off when door
is closed.
4.2 Output and accessories
Output Description
TC
Automatic closing time. From 0 to 120 s, with TC<MAX.
With TC=MAX automatic closing is disabled.
The count starts with door stopped for time set with TC.
After
the
intervention of a safety (1-8), the countdown begins with the open door and lasts for the whole
time set with TC.
With TC=MAX or contact 1-9 open, automatic closing is disabled.
If disabled with 1-9, automatic closing is re-enabled, once the contact 1-9 has been closed again, only
after a control 1-5 or a remote control.
R1
Obstacle
thrust
adjustment. The control panel is equipped with a safety device that stops the opening
operation and stops and inverts the closing operation in the presence of an obstacle.
With R1=MIN there is maximum obstacle sensitivity (minimum thrust).
With R1=MAX the detection function is deactivated (maximum thrust).
5. SETTINGS
5.1 Trimmer
71R