GENERAL SAFETY PRECAUTIONS
This installation manual is intended for professionally
competent personnel only.
Installation, electrical connections and adjustments must be
performed in accordance with Good Working Methods and in
compliance with applicable regulations. Before installing the
product, carefully read the instructions. Bad installation could
be hazardous.
The
packaging materials (plastic, polystyrene, etc.) should not
be discarded in the environment or left within reach of children,
as these are a potential source of hazard. Before installing the
product, make sure it is in perfect condition.
D
o
not install the product in an explosive environment and atmo-
sphere: gas or inflammable fumes are a serious hazard risk.
B
efore installing the motors, make all structural changes relating
t o safety clearances and protection or segregation of all areas
where there is risk of being crushed, cut or dragged, and danger
areas in general.
Make
sure
the existing structure is up to standard in terms of
strength and stability.
The motor manufacturer is not responsible for failure to use
Good Working Methods in building the frames to be motorised
or for any deformation occurring during use.
T
h
e safety devices (photocells, safety edges, emergency stops,
etc.) must be installed taking into account: applicable laws and
directives, Good Working Methods, installation premises, system
operating logic and the forces developed by the motorised door
or gate.
The
safety
devices must protect any areas where the risk exists
of being crushed, cut or gragged, or where there are any other
risks generated by the motorised door or gate. Apply hazard
area notices required by applicable regulations.
Each
installation
must clearly show the identification details of
the motorised door or gate.
Before
making
power connections, make sure the plate
details correspond to those of the power mains.
Fit
an
omnipolar disconnection switch with a contact opening
gap of at least 3 mm. Make sure an adequate residual current
circuit breaker and overcurrent cutout are fitted upstream of
the electrical system. When necessary, connect the motorised
door or gate to a reliable earth system made in accordance with
applicable safety regulations. During installation, maintenance
and repair, interrupt the power supply before opening the lid to
access the electrical parts.
T
o
handle electronic parts, wear earthed antistatic con-
ductive bracelets.
The
motor
manufacturer declines all responsibility in the event
of component parts being fitted that are not compatible with the
safe an correct operation.
F
or repairs or replacements of products only original spare parts
must be used.
The
installer
shall provide all information relating to automatic,
manual and emergency operation of the motorised door or gate,
and provide the user with operating instructions.
MACHINERY DIRECTIVE
Pursuant to Machine Directive (98/37/EC) the installer who mo-
torises a door or gate has the same obligations as a machine
manufacturer and shall:
-
prepare
technical documentation containing the documents
indicated on Schedule V of the Machine Directive;
(The
technical documentation shall be kept and placed at
the disposal of competent national authorities for at least ten
years starting on the date of manufacture of the motorised
door);
-
d
raw up the EC declaration of conformity according to Sche-
dule II-A of the Machine Directive;
-
affix the CE mark on the motorised door pursuant to para.
1.7.3 of Schedule I of the Machine Directive.
F
or more details, refer to the “Guidelines for producing technical
documentation” available on Internet at the following address:
www.ditec.it
OPERATING INSTRUCTIONS
Service class: 3 (minimum 30 cycles a day for 10 years or 60
cycles a day for 5 years)
Use: FREQUENT (for
multi-family entrances or small condomi-
niums with frequent car or pedestrian transit)
-
T
he operating performance specifications refer to the re-
co
mmended weight (about 2/3 of maximum allowed weight).
Use with maximum allowed weight could reduce the above
performance specifications.
- The service class, operating times and number of conse-
c
u
tive cycles are merely approximate. These have been
statistically determined in average conditions of use and
are not certain for each single case. They refer to the pe-
riod
when the product operates without the need for special
maintenance.
-
Each
automatic entrance features variable factors such as:
friction, balancing and environmental conditions that can
substantially change both the duration and operating quality
of the automatic entrance or part of its components (including
automatic system). It is up to the installer to adopt adequate
safety coefficients for each single installation.
MANUFACTURER’S DECLARATION
(Directive 98/37/EC, Schedule II, part B)
Manufacturer: DITEC S.p.A.
Address: via Mons. Banfi, 3
21042 Caronno P.lla (VA) - ITALY
D
eclares that the automatic system for spring balanced up and
over doors and sectional overhead doors of the GLOBE series:
- is
manufactured to be incorporated into a machine or to be
assembled with other machines to make a machine considered
by Directive 98/37/EC;
-
is
in conformity with the conditions of the following other EC
directives:
R&TTE Directive 1999/5/EC,
Electromagnetic compatibility directive 89/336/EEC;
Low-voltage directive 73/23/EEC;
and further certifies that the machine shall not be commissioned
until the machine into which it is to be incorporated or of which
it is to become a component part has been identified and has
been declared in conformity with the conditions of the Directive
98/37/EC and the transposing national legislation.
Caronno Pertusella, Fermo Bressanini