Diagnostic Procedures Americana and New Generation Refrigerators
Component Diagnostic Question Action Based On Status Page
Is E4 displayed? (New Generation
models only)
Is the right temperature setting light
blinking? (First generation DMR702 and
DMR702-D models only)
1. Confirm that the voltage supplied to the
lower control module at terminal6 is
between 10.5–18VDC.
2. If the voltage is out of specification,
perform a diagnosis on the power supply.
15
If the error persists, replace the lower control
module.
48
Orifice
Does the refrigerator operate in electric
mode but not in gas mode?
Is the check indicator lamp on?
(Americana models only)
Is E3 displayed? (New Generation
models only)
Are two thermostat range setting lights
flashing? (First generation DMR702 and
DMR702-D models only)
1. Check the part number and size of
the orifice against the parts list for the
refrigerator model.
2. If the number does not match, replace the
orifice with the correct part.
42
1. Remove the orifice.
2. Hold the orifice up to a light. You should
be able to see through the orifice and it
should appear pink in color.
I
Do not blow compressed air or stick
anything into the orifice. The orifice has
a man-made ruby inset that is easy to
dislodge. If dislodged, the orifice must
be replaced.
3. If the orifice is clogged, soak it in an
alcohol-based solvent for one hour.
4. Remove it from the cleaner and let it air
dry.
5. If the orifice is still clogged, replace it.
Relay (RM1350 Model Only)
Is the refrigerator or freezer not cold
enough in any operating mode?
Does the ice maker not produce ice?
1. Confirm that the voltage from the lower
control module to terminal86 is between
10.5–18VDC.
2. If the voltage is out of specification,
perform a diagnosis on the power supply.
15
1. Test for continuity between terminal30
and terminal87.
2. Test terminal85 to confirm that there is no
continuity to the chassis ground.
43
3. If the relay fails either test, replace it. 43
Thermal Fuse
Is the refrigerator not operating and the
interior light not on?
Is E3 displayed? (New Generation
models only)
Are two thermostat range setting lights
flashing? (First generation DMR702 and
DMR702-D models only)
1. Test for continuity through the thermal
fuse.
2. If there is no continuity, replace the
thermal fuse.
44

Table of Contents

Other manuals for Dometic DM2882

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic DM2882 and is the answer not in the manual?

Dometic DM2882 Specifications

General IconGeneral
BrandDometic
ModelDM2882
CategoryRefrigerator
LanguageEnglish

Related product manuals