Technical data RC10.4 70, RC10.4 90
30
13 Technical data
The coolant circuit contains R-134a.
Contains fluorinated greenhouse gases
Hermetically sealed equipment
RC10.4 70 RC10.4 90
Gross capacity: 69 l 90 l
Net capacity (without freezer
compartment):
64 l 85 l
Capacity freezer compartment: 7.5 l
Connection voltage: 12 Vg or 24 Vg
Average power consumption:
12 Vg:
24 Vg:
42 W
58 W
45 W
61 W
Energy consumption: ≤ 0.45 kWh/24 h (PERFORMANCE mode)
≤ 0.35 kWh/24 h (SILENT mode)
Cooling device compartment temperature: <+5 °C (PERFORMANCE mode)
Freezer compartment temperature: < –12 °C (PERFORMANCE mode)
Relative humidity: max. 90 %
Short-term inclination: max. 30°
Climate class: T
Coolant quantity: 40 g 43 g
CO
2
equivalent: 0.057 t 0.061 t
Global warming potential (GWP): 1430
Noise emission: 40 dB(A) (PERFORMANCE mode)
37 dB(A) (SILENT mode)
Dimensions (W x H x D): 420 x 821 x 450 mm 420 x 975 x 485 mm
Weight: 19.5 kg 21.4 kg
Test/certificates:
RC10.4-IO-EN-DE-FR-NL.book Seite 30 Montag, 10. September 2018 11:15 11