Refrigerator operation
4.14 Troubleshooting
Before notifying the authorised Service Center,
please check whether:
the instructions in section "Operating the
refrigerator" have been observed.
the refrigerator stands level.
it is possible to operate the refrigerator with
any available power source.
Possible cause Action you can take
Inadequate ventilation to the unit.
Thermostat setting is too low.
The condenser is heavily frosted.
Too much warm food has been stored inside within
short period of time.
The appliance has been running for only a short period
of time.
Ambient temperatures too high.
Check that the ventilation grilles are not covered.
Set thermostat to a higher level.
Check that the refrigerator door closes properly.
Allow warm food to cool down before storage.
Check whether the cooling compartment works after
approx. 4 - 5 hours.
Regularly remove ventilation grilles.
Possible cause Action you can take
Gas cylinder empty.
Upstream shut-off device closed.
Air in the gas pipe.
Change gas cylinder.
Open shut-off device.
Switch off the appliance and start again. Repeat this
procedure 3 - 4 times, if necessary.
Possible cause Action you can take
On-board fuse defective.
On-board battery discharged.
Engine not running.
Heating element defective.
Fit new fuse.
Check battery, charge it.
Start engine.
Please inform the Dometic Customer Services.
Possible cause Action you can take
On-board fuse defective.
Vehicle not connected to mains supply voltage.
Heating element defective.
Fit new fuse.
Make a connection to a mains power supply.
Please inform the Dometic Customer Services.
Failure: The refrigerator does not cool sufficiently.
Failure: The refrigerator does not cool in gas operation mode.
Failure: The refrigerator does not cool in 12V operation.
Failure: The refrigerator does not cool in 230V operation.