- 18 -
TROUBLESHOOTING
SYMPTOM CHECK/REMEDIAL ACTION
Refrigerator stops cooling Immediately turn the refrigerator off and contact a Dometic dealer or Service Center.
NOTE! Do not leave it running for an extended period of time, and never try to solve the
problem by repeatedly restarting the refrigerator.
Do not use the refrigerator until it has been repaired.
Refrigerator emits an am-
monia smell
Immediately turn the refrigerator off at front control panel.
Do NOT open refrigerator doors.
Open coach windows and door (to air out the coach) and evacuate.
Turn off manual LP gas valve at rear of refrigerator.
Disconnect the 120 VAC power at rear of refrigerator.
Contact a Dometic dealer or Service Center for repair.
Do not use the refrigerator until it has been repaired.
Refrigerator or freezer is
not cold enough
Check the thermostat and adjust if necessary.
Is there a power failure?
Is the refrigerator level? (Due to the nature of its operation it is important to keep an
absorption refrigerator level.)
Door closing properly? Check the door gasket.
Heavy frost build-up on evaporator ns? To prevent frost buildup do not leave the unit’s
door open longer than necessary.
Over packed refrigerator? The unit will have to work harder if the refrigerator is stuffed,
and results in higher cabinet temperatures. Arrange the food in the unit to allow for free
air circulation.
Refrigerator does not work
on electric
Is the plugrmly connected to the receptacle? Is the receptacle energized? Check the
receptacle by plugging in another appliance.
Is there a power failure?
Blown fuse. Turn refrigerator off and contact a Dometic dealer or Service Center for repair.
Refrigerator does not work
in gas operation mode
LP gas bottle empty? Change the gas bottle.
Air in the gas pipe? Remove air by repeating the ignition sequence.
If the problem persists, turn refrigerator off and contact a Dometic dealer or Service Center
for repair.
Refrigerator emits an odor
from fumes
Dislocated or damaged burner. Turn refrigerator off and contact a Dometic dealer or Service
Center for repair.
Dirty ue tube. Turn refrigerator off and contact a Dometic dealer or Service Center for repair.
“LP” is ashing
(The message alternates
between “LP” and the
fresh food compartment
temperature.)
LP gas ignition failed. The refrigerator went through a complete ignition sequence, and the
burner did not light. Turn refrigerator OFF and then back ON to return to normal operation.
Air in the gas line? After changing a gas bottle or after a long shutoff period, the gas line is
likely to be lled with air. You may have to repeat the lighting procedure (45 seconds) by
turning the refrigerator off and on several times in order to purge the air out of the gas lines.
LP gas bottle empty and needs replacing.
Obstruction in or on the burner or burner jet, or burner jet is clogged and should be cleaned.
Turn refrigerator off and contact a Dometic dealer or Service Center for repair.
If the problem persists and the refrigerator is still not working properly, turn refrigerator off and contact your nearest Service
Center. State the problem, model, product, and serial number. These details are stated on the data label inside the fresh
food compartment.
TROUBLESHOOTING TABLE
If you run into a problem, refer to the troubleshooting table below. If an error code is displayed, please see “Error Codes”
for more information.

Other manuals for Dometic RM1350

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic RM1350 and is the answer not in the manual?

Dometic RM1350 Specifications

General IconGeneral
BrandDometic
ModelRM1350
CategoryRefrigerator
LanguageEnglish

Related product manuals