45
Fig.
15
i
i
.
/
/
i.
&l,/
’
/
,,,
’
g
,.,’
,
/’
Fig. 76
.
&!I!
_-
To replace flint, follov these steps:
1.
Remove the
2.
Remove the
3.
Remove cap
outer burner shield by means of loosening the
two
screws A (Fig. 75).
lighter by loosening the screw B retaining the lighter (Fig,
76).
C and
remOve
the spring D and tap out any remaining piece of flint
__
.
and fit a nev
flxnt.
Be sure not to lose the small helical spring vhich presses the flint against
the serrated wheel.
Replacement of the serrated vheel
-
RM24
If after several years of use the lighter does not function properly even
with
a
new flint,the serrated vheel might be worn out and needs to be replaced.
1.
Release the lighter as described above.
2.
Unscrew the rod from the serrated wheel and fit a new wheel.
CAUTION
:
The rod has to be unscrewed anti-clockwise.
41.
PIEZO LIGHTER (Fig. 77)
Fig. 77
The
RM36C,
RM46, RM47,
RM66,
RM67,
RM76
and RM77 models are equipped with a Piero
crystal lighting device vhich creates a spark over the burner when the button E is
pushed in fully (see fig. 72).