10
Additional features RMD 8xxx
Failures are indicated by flashing of the red
external failure indicator LED.
Should the door be kept open for too long
(more than 2 minutes), the blue external
LED starts flashing until the door is closed.
Only with AES models RMD 8xx5 :
Should the electronic control detect any fai-
lure, an acoustic signal will sound (pulsing
whistle tone) for 30 seconds (. It is repeated
every hour, if the failure ist not resolved.
1.6 General
Description of model
A description of the components of RM
8xx0 (piezo) models can be found in the
instruction 599 5175-18 EN (RM 7xxx
models).
Fridges of the 8-series with manual ignition
are provided with a battery igniter and a Gas-
Operation-Indicator (Galvanometer ).
For using the locking button, the panel is for-
med asymmetric (recess on one side). I.e.
changing the door rabbet is not possible any
more. The rabbet has to be determined befo-
re the fridge is installed.
The product number controls the side of the
door rabbet. Please notify this, if the door or
the fridge is exchanged!
At all RM 8xxx models the door seal is
exchangeable.
Additional features AES
Should the door be kept open for too long
(more than 2 minutes), an acoustic signal is
initiated (pulsing whistle tone).
Should the electronic control detect any fai-
lure, an acoustic signal will sound (pulsing
whistle tone) for 60 seconds .
Additional features MES / AES
If the door is open, the interior lighting is swit-
ched off automatically after 2 minutes.
10 seconds after the button has been pushed
for the last time, the indication (LED) swit-
ches into the dim-mode. The dim-mode is
reversed by pushing a button. The desired
function is activated by pushing the button
again.
Failures are indicated by flashing of the failu-
re indicator LED..