15
Fig. 14
Dometic recommends the A 1625 ventilation
and flue gas extraction system which has
been tested and approved for this purpose.
These ventilation grills provide the required
open cross-section of at least 250 cm².
4.3 Installing the ventilation
system
AS 1625
Fig. 15
AS 1635
Top ventilation grille
with flue
Lower
ventilation grille
4.3.1 Ventilation systems for refrigera-
tors of 100 ltr. cap. or less
Dometic recommends the larger LS 300
(L500, NZ) side ventilation grilles be used for
both the top and lower side ventilation of the
refrigerator. Alternatively, the installation of the
lower ventilation grille (LS 300 / L500) with the
roof exhaust is also acceptable.
The ventilation grilles must have an open
cross-section of at least 450 cm². This is
achieved by using the Dometic LS300 / L500
absorber ventilation and air extraction system
which has been tested and approved for this
purpose.
4.3.2 Ventilation systems for refrigera-
tors larger than 101 ltr. cap.
Positioning of roof exhaust vent and lower
ventilation grille LS300 or L500 (NZ)
Fig. 16
Minimum height of ventilation
roof vent
H
LS300
or
L500
(NZ)
optional ventilation aperture
Ø min 40 mm
Installation
Flue kit
3776

Other manuals for Dometic RML8 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic RML8 Series and is the answer not in the manual?

Dometic RML8 Series Specifications

General IconGeneral
BrandDometic
ModelRML8 Series
CategoryRefrigerator
LanguageEnglish

Related product manuals