24
[1] Local Walk Test is selected the keypad will sound 3 quick beeps and
return to the normal disarmed display. The user can then test each
detector on the partition and any zone violated will cause the burglary
bell/siren to sound for 2 seconds, confirming that the detectors are
working properly. Note that fire bell/sirens will not sound, and all zones
including fire zones will activate burglar bell/siren alarms for 2 seconds
in walk test mode.
During walk test mode no alarms on that partition will be transmitted to
the monitoring station. However, if a printer module (PC4400) is installed
on the system the zones violated will be printed.
[2] Local + Comm. (Communications) Test will operate the same as local
walk test mode except that alarms will be transmitted to the monitoring
station in order to test communications.
[3] Disable Walk Test will disable walk test mode, and the partition returns
to its normal disarmed state. Walk test mode will also be automatically
disabled if the partition is armed.
DOOR STRIKE
[✱]+[7] or [✱]+[7]+[ACCESS CODE]
Entering [✱] [7] or [✱] [7] [Access Code] will activate a utility output for a
preset time, during which the keypad buzzer will sound. The utility output
may be used on an armed or disarmed partition, and the installer may
program it so that an access code is required to activate the utility output.
Note: The Door Strike output will be deactivated at the end of the
standard exit delay.
INSTALLER’S PROGRAMMING COMMANDS
[✱]+[8]+[INSTALLER’S CODE]
This command is used by the installer to program the PC4020.
“AT-HOME” ARMING
[✱]+[9]+[ACCESS CODE]
Entering [✱] [9] before the arming code, arms the panel without any entry
delay on the delay zones and bypasses zones that are defined as “Home-
Away”. This command is used for arming the system while at home. Once
the panel is Armed in this mode, using [✱] [1] will remove the bypass from
those zones defined as “Home-Away” if they have NOT been manually
bypassed. The [✱] [1] command, as used here, only removes the bypass
from zones that were automatically bypassed with the [✱] [9] command.
If [✱] [9] proceeds a multi partition access code used to arm any partition,
the partition(s) will be at-home armed.