[6] Closing Confirmation Enabled / Disabled
ON = Closing Confirmation Enabled. When an Access
Code is entered to arm the system, the Exit Delay time
will not begin until one of the following events occurs:
• The closing is successfully transmitted to the
monitoring station. When the closing is transmitted, the
keypad will sound an acknowledgement tone to
indicate that the monitoring station has been advised of
the closing. The Exit Delay will then begin.
• The closing is not successfully transmitted to the
monitoring station. If the closing cannot be transmitted,
a Failure To Communicate Trouble will be generated.
The Exit Delay time will begin once the trouble
condition is indicated on the keypad.
• The user may re-enter their Access Code to initiate the
Exit Delay
OFF = Closing Confirmation Disabled.
The Exit Delay time will commence once an Access
Code is entered to arm the system.
Notes:
Back-up to Second Telephone Number cannot be
used with the Closing Confirmation feature.
The Closing Confirmation feature cannot be used
with the Escort Voice Assisted Security Module.
The Closing Confirmation feature cannot be used
with Split Arming. (sections [29] to [32])
The Closing Confirmation feature cannot be
used with the Exit Delay Termination feature.
(section [60] Light [7] OFF)
[7] Exit Delay Termination Enabled / Disabled
ON = Exit Delay Termination Enabled.
The Exit Delay will be terminated once the Delay Zone for
the entry/exit door or area is restored. All audible options
associated with the Exit Delay will be silenced when the
Exit Delay is terminated.
OFF = Normal Exit Delay.
The Exit Delay timer will continue to count even after the
Delay Zone for the entry/exit door or area is restored. All
audible options associated with the Exit Delay will
function until the time programmed for the Exit Delay has
elapsed.
Notes:
Split Arming cannot be used with the Exit Delay
Termination feature. (sections [29] to [32])
Closing Confirmation cannot be used with the Exit
Delay Termination feature. (section [60] Light [6]
OFF)
[8] For Future Use
OFF = Zone Light 8 must be OFF at all times.1
[90] Installer’s Lockout Enable
This feature is enabled by entering [90] while in the Installer’s
Programming mode. A factory default (hardware or software)
will not reset the Installer’s Code or the download access
code once this feature is enabled. A panel that has this
lockout feature enabled will give a distinctive audible
indication upon power up. This indication is the phone line
relay clicking ten times. Make sure that your new Installer’s
Code has been entered correctly before enabling this
feature because there is no way of re-entering the
programming mode without the new Installer’s Code. Even a
reset to the factory default will not change the Installer’s
Code back to default.
[91] Installer’s Lockout Disable
Entering [91] when in the Installer’s Programming mode will
disable the Installer’s Lockout feature.
Note: Panels returned to DSC with the Installer’s Lockout
feature enabled and no other apparent problems will be
subject to an additional service charge.
WWW.DIYALARMFORUM.COM

Table of Contents

Other manuals for DSC PC3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC PC3000 and is the answer not in the manual?

DSC PC3000 Specifications

General IconGeneral
BrandDSC
ModelPC3000
CategorySecurity System
LanguageEnglish

Related product manuals