40
KEYPAD HOOKUP
1. Each keypad has four coloured leads: red (RED), black (BLK), yellow (YEL), and green (GRN). Connect the leads to the
corresponding terminals on the panel.
2. Up to 3 keypads may be connected in parallel. DO NOT connect multiple keypads on the same loop.
3. The wiring table gives the maximum wire run for various gauges of wire. Wire run lengths are calculated on the
maximum current drawn by the keypad (when all lights are ON).
4. For standby loading purposes, it is recommended that a current draw of 20 mA per keypad be used. This represents the
panel in a disarmed state with two zones in alarm.
Note: If two wires of the same gauge are paralleled, the run length can be doubled. e.g. If eight 22AWG wires (2 RED, 2
BLK, 2 YEL, 2 GRN) are run to the keypad, the run length would double from 540 feet (164.5 m) to 1080 feet (329 m).
FIRE CIRCUIT HOOKUP
Loop
Current
mA
50 2750/838
1375/419
690/210
460/140
345/105
1740/530
870/265
435/132
290/88
215/65
1090/332
545/166
270/82
180/55
135/41
869/264
435/132
217/66
144/33
108/33
433/131
217/66
108/33
144/43
54/16
100
200
300
400
Maximum wire run to EOL relay in feet/meters
AWG14 AWG16 AWG18 AWG19 AWG22
AWG14 15500 / 4724
9740 / 2968
6120 / 1865
4860 / 1481
3840 / 1170
3060 / 932
2420 / 737
AWG16
AWG18
AWG19
AWG20
AWG21
AWG22
Wire
Gauge
Maximum Run to End of Line Resistor
(feet / meters)
Bell
Current
mA
50 2750/838
1375/419
690/210
460/140
345/105
275/83
230/70
195/59
1740/530
870/265
435/132
290/88
215/65
170/52
140/43
125/38
1090/332
545/166
270/82
180/55
135/41
105/32
90/27
80/24
869/264
435/132
217/66
144/33
108/33
86/26
72/22
62/19
433/131
217/66
108/33
144/43
54/16
43/13
36/11
30/9
100
200
300
400
500
600
700
Maximum wire run to EOL resistor in feet/meters
AWG14 AWG16 AWG18 AWG19 AWG22
Wire
Gauge
AWG24 330 / 100
540 / 164
850 / 259
1000 / 305
1360 / 414
AWG22
AWG20
AWG19
AWG18
Maximum Run Length - Keypad to Panel
(feet/meters)
Smoke detector must be latching type (ESL 446C).
To reset smoke detectors, press and hold [Q][4].
ALARM
CONTACT
IN
IN
OUT
OUT
ALARM
CONTACT
IN
IN
OUT
OUT
AUX
+
AUX
SW
AUX
+
BELL FIRE
+
HORN
ALARM INITIATING LOOP
700 mA MAX.
BELL LOOP
700 mA MAX
4-WIRE SMOKE
DETECTOR POWER
12 VDC 400mA MAX
RED
WHT
SMOKE DETECTOR POWER
SUPERVISION RELAY
(DSC RM-1)
12 VDC 35 MA
BLK
GRN
EOLR-1
WWW.DIYALARMFORUM.COM