2000 Series Disc Valve Motors
2000 SerieS diSc valve geroler motor C-MOLO-TM010-E1 June 2018 www.eaton.com
40. Install tie bolts. If you use alignment Studs, install
2 bolts opposite the studs. Finger tighten the bolts.
Remove the alignment studs and replace with the
two remaining bolts. Torque all four bolts alternately
to 50 Nm [450 lb-in].
41. Install seal on case drain plug then install in valve
housing. Torque to 6 Nm [50 lb-in.]
Case Drain Plug with Seal
Tie Bolts
Exclusion Seal
Castle Nut
Bearing Housing
Seal
Shaft Seal
Shaft and Bearing
Assembly
Shaft Face Seal
Back-up Washer
On wheel motors, a different bearing housing is used, see
Figure 19. Other than this the parts are the same as the
standard motor and the same disassembly and reassembly
procedures apply.
Standard/Wheel motor with seal guard
Installation of seal guard:
After completing assembly of the shaft and bearing
assembly into the bearing housing, press the seal guard
onto the shaft with a tool that will provide an even push
over the seal. This tool must bottom out against the bearing
housing and provide a 4,5 mm [.177 inch] stop for the seal
guard. Applicable for standard and wheel mount motors.
Exclusion Seal
Housing with Seal Guard Groove
Seal Guard
4,40[.177]
Reassembly
Wheel motor
Figure 19.
Figure 18.
Figure 20.

Other manuals for Eaton Char-Lynn 2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton Char-Lynn 2000 Series and is the answer not in the manual?

Eaton Char-Lynn 2000 Series Specifications

General IconGeneral
BrandEaton
ModelChar-Lynn 2000 Series
CategoryEngine
LanguageEnglish

Related product manuals