Release Yoke and Cross-Shaft(s) Removal and Installation | Service Procedures TRSM0940
Release Yoke and Cross-Shaft(s) Removal
Note: The Transmission and ECA must be removed prior to
removing the Release Yoke and Cross-Shaft(s).
1. Remove
the upper and lower Cross-Shaft mounting
cap screws and lock washers from the Release Yoke.
2. Remove the
Cross-Shaft Plug with O-ring.
3. Push the upper
Cross-Shaft up out of the Release Yoke
and remove the Yoke.
4. Remove the lower
Cross-Shaft and Release Yoke.