4 Assembly and connection
Personnel:
n
Mechanic
n
Qualified electrician
n
Service personnel
n
Specialist
Protective equipment:
n
Protective gloves
n
Protective eyewear
n
Safety shoes
NOTICE!
Material damage due to using incorrect tools.
Use of the wrong tool can cause material damage. Only use the correct
tools.
DANGER!
Damage and injury can occur as a result of unprofessional work carried
out during installation.
–
installation work must be performed only by authorised/ trained experts in
accordance with valid local regulations.
– The safety regulations and required protective clothing (PPE) must be
complied with when working with chemicals. Attention must be paid to the
information included on the product data sheet for the dosing medium used.
NOTICE!
General instructions for installation and assembly:
–
The pump must be installed at an easily accessible, frost-protected
location.
– The ambient conditions given in the "Technical data" must be observed.
– The pump must be installed in a horizontal position.
4.1 Installation
The graphics shown in this chapter are schematic diagrams and may differ
from the original.
Since all pump housings support the same mounting variants, the different
mounting types are shown using an EcoPro metering pump.
DANGER!
The mounting plate can be mounted on a suitable container
. In this case,
you must not drill new holes to prevent the metering medium from offgassing.
Only containers that have been prefabricated for mounting on pumps using a
threaded insert may be used.
Assembly and connection
15 10240750 Ver. 4-11.2023