9.3 Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar 8 kW
Gas replace‐
ment:
G30 (3+) 28-30 mbar 567 g/h
G31 (3+) 37 mbar 557 g/h
Electric supply: 220-240 V ~ 50-60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse
Appliance category: II2H3+
Gas connection: R 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER kW INJECTOR MARK
Rapid 3,0 0,75 119
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Rapid 2,8 0,75 86 204 200
Semi-rapid 2,0 0,45 71 145 143
Auxiliary 1,0 0,33 50 73 71
10. ENERGY EFFICIENCY
10.1 Product Information according to EU and UK Ecodesign regulations
Model identification EGS64041X
Type of hob Built-in hob
Number of gas burners 4
18 ENGLISH