Figure 11 Bezel Installation
Confirming the RAID rebuild
After replacing a hard drive, the RAID system automatically begins rebuilding the data.
Typically, the hard drive LED begins blinking while the hard drive is rebuilding. Confirm
that the rebuild is successful by performing the following steps:
Procedure
1. List the tasks currently running on the disk controller by typing:
arcconf getstatus 1
Output similar to the following is displayed:
Controllers found: 1
Logical device Task:
Logical device : 0
Task ID : 32
Current operation : Rebuild
Status : In Progress
Priority : Low
Percentage complete : 1
Command completed successfully.
Note the ID number for the rebuild task.
2. Change the rebuild task to high priority by typing:
arcconf setpriority 1 <ID> HIGH
where
<ID>
is the task ID number noted in the previous step.
3. View the rebuild status by typing:
avsysreport pdisk pdisk=<Slot Number>
where <Slot Number> is the ID number that you noted previously. For example:
avsysreport pdisk pdisk=1
Replacing a Hard Drive
22 EMC Avamar Data Store Gen4T Customer Service Guide