Page #30 background imageLoading...
Page #30 background image
Figure 14 Power Supply Installation
2. Insert the replacement power supply into the SP module and push until it clicks into
place.
3. Connect the AC power cord to the replacement power supply and fasten the retaining
clip to secure the cord.
4. Allow several seconds for the node to recognize the power supply and determine
whether it is working properly. The AC Good and DC Good LEDs should illuminate
green. The Attention LED should stay off.
Verifying the replacement power supply
Procedure
1. Type the following command:
avsysreport power-supply
Output similar to the following is displayed:
=== Power supply redundancy
Status : Ok
Redundancy State : Fully Redundant
=== Power supplies
Power Supply ID : 0
Status : Ok
Location : PSA
Operational State : Inserted, Power Good
Firmware Revision : 4.20.0.1
Serial Number : FPSAG144900460
Power Supply ID : 1
Status : Ok
Replacing a Power Supply
30 EMC Avamar Data Store Gen4T Customer Service Guide

Questions and Answers: