149
Diagnostics and Troubleshooting
High DC Bus Reset Button or Input Line Yes
Low DC Bus Reset Button or Input Line Yes
Encoder State Cycle Power Yes
Encoder Hardware Cycle Power Yes
Motor Overtemp
Allow Motor to cool down,
Reset Button or Input Line
Yes
RMS Shunt Power
(EN drives only)
Reset Button or Input Line Yes
Overspeed Reset Button or Input Line Yes
Following Error
(Pulse mode only)
Reset Button or Input Line Yes
Travel Limit +/- Auto No
All "On"
Normally "On" for one
second during power-up
Yes
Display Fault Action to Reset Bridge Disabled