8
Epsilon Eb and EN Drives Reference Manual
Pulse frequency > 250 kHz
Pulse command cable length > 25 feet
Noisy electrical environments
Differential input circuit specifications:
Input frequency maximum 2 Mhz
Input device: AM26C32
Input impedance 12 Kohms each input
Maximum voltage applied to input pins (A, A/) or (B, B/ )
Single Ended (referenced to 0V drive logic) +/-10V
Differential (referenced to mating differential input) +/-10V
Maximum common mode voltage +/-7 V
Minimum differential voltage required 200 mV
Input voltage hysteresis 60 mV
Single ended input circuit specifications:
Single ended input specifications:
1 MHz maximum input frequency
Internal 330 ohm pull-up to 5 Volt (non-isolated)
1.5 Volt low level
3.5 Volt high level
Output driver requirements:
15 mA sinking (open collector)
5 Volt capacity
ECI-44 Terminal
Command
Connector Pin #
Pulse-Direction
Signal
Pulse-Pulse
Signal
Pulse Quadrature
Signal
Sync Enc In “A” 27 Pulse Pulse + A
Sync Enc In “A/” 41 Pulse/ Pulse +/ A/
Sync Enc In “B” 26 Direction Pulse - B
Sync Enc In “B/” 40 Direction/ Pulse -/ B/
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for Emerson Control Techniques EN Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Control Techniques EN Series and is the answer not in the manual?

Emerson Control Techniques EN Series Specifications

General IconGeneral
BrandEmerson
ModelControl Techniques EN Series
CategoryDC Drives
LanguageEnglish

Related product manuals