201
Specifications
Power Dissipation
In general, the drive power stages are 90 to 95 percent efficient depending on the actual point
of the torque speed curve the drive is operating. Logic power losses on the EN drive is 11 W
minimum to 21 W depending on external loading such as FM modules and input voltages.
Logic power losses on the Epsilon drive are 11 W with normal loads to 15 W with additional
loads such as external encoder and low input voltage (<22 VDC on A.P.S. or 120 VAC on
AC input).
The values shown in the table below represent the typical dissipation that could occur with
the drive/motor combination specified at maximum output power.
Drive Model
Logic Power Losses
(typ) Drive
(Pld) (Watts)
Maximum Power Stage
Losses
(Pp) (Watts)
Total
Power Losses
(Watts)
EN-204/NT-320
19
105 124
EN-204/MG-205 30 52
EN-204/MG-208 50 72
EN-204/MG-316 82 104
EN-208/NT-320 135 154
EN-208/NT-330 175 194
EN-208/NT-345 185 204
EN-208/NT-355 211 230
EN-208/MG-340 160 182
EN-208/MG-455 200 222
EN-214/NT-345 192 211
EN-214/NT-355 221 240
EN-214/MG-490 300 322
EN-214/MG-4120 430 452
Eb-202/NT-207
11
25 36
Eb-202/NT-212 30 41
Eb-202/MG-205 25 36
Eb-203/NT-207 30 41
Eb-203/NT-212 55 66
Eb-203/MG-208 55 66
Eb-203/MG-316 60 71
Eb-205/MG-316 72 83
Eb-205/MG-340 88 99
Eb-205/NT-212 55 66
Eb-205/NT-320 88 99
Eb-205/NT-330 88 99
Eb-205/NT-345 88 99
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com