1.2 Safety statements
Refrigerant compressors must be employed only for their intended use. The system has
to be labelled according to the applicable standards and legislation.
Only qualified and authorized HVAC or refrigeration personnel are permitted to install
commission and maintain this equipment. Only competent personnel (as specified in
EN 13313) qualified for flammable refrigerant handling is permitted to commission, initiate
and maintain the compressor/refrigeration systems; non-trained personnel, including the
user, are not allowed to do so and must call on an expert.
The maximum refrigerant charge is specified in standards such as, but not limited to
EN 378, EN 60335-2-40 and EN 60335-2-89. The system designer shall implement all safety
measures defined by the applicable standards and shall not exceed the maximum
refrigerant charge.
If a flammable atmosphere is detected, immediately take all necessary precautions to
mitigate the risk as determined in the risk assessment.
Electrical connections must be made by qualified electrical personnel.
All valid standards for connecting electrical and refrigeration equipment must be
observed.
The national legislation and regulations regarding personnel protection must be observed.
Use personal safety equipment. Safety goggles, gloves,
protective clothing, safety boots and hard hats should be worn
where necessary.
1.3 General instructions
WARNING
Pressurized system! Serious personal injuries and/or system
breakdown! Accidental system start before complete set-up must be avoided.
Never leave the system unattended without locking it out electrically when it is
on vacuum and has no refrigerant charge, when it has a holding charge of
nitrogen, or when the compressor service valves are closed.
WARNING
System breakdown! Personal injuries! Only approved refrigerants and
refrigeration oils must be used.
WARNING
High shell temperature! Burning! Do not touch the compressor until it has
cooled down. Ensure that other materials in the area of the compressor do not
come into contact with it. Lock and mark accessible sections.
CAUTION
Overheating! Bearing damage! Do not operate compressors without
refrigerant charge or without being connected to the system.
CAUTION
Contact with POE! Material damage! POE lubricant must be handled
carefully and the proper protective equipment (gloves, eye protection, etc.)
must be used at all times. POE must not come into contact with any surface
or material that it might damage, including without limitation, certain polymers,
eg, PVC/CPVC and polycarbonate.
IMPORTANT
Transit damage! Compressor malfunction! Use original packaging. Avoid
collisions and tilting.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Copeland Scroll YBVH021 1U-3E9 and is the answer not in the manual?

Emerson Copeland Scroll YBVH021 1U-3E9 Specifications

General IconGeneral
BrandEmerson
ModelCopeland Scroll YBVH021 1U-3E9
CategoryAir Compressor
LanguageEnglish

Related product manuals