Table 8 – CoreSense
Communications LED Flash Code Information
TheashcodenumbercorrespondstothenumberofLEDashes,followedbyapause,andthentheashcodeisrepeated.
Alockoutconditionproducesaredash,followedbyapause,asolidred,asecondpause,andthenrepeated.
Status Fault Condition Code Fault Description
Code Reset
Description
Troubleshooting Information
Solid Green Normal Operation
Module is powered and
operation is normal
N/A N/A
Solid Red
Module
Malfunction
Module has internal fault N/A
1) Reset module by removing
power from T2-T1
2) Replace module
Warning LED Flash
Green
Flash Code 1
Loss of
Communication
Module and master controller
have lost communications
with each other for more than
5 minutes
When
communications
areconrmed
1) Check the control wiring
2) Verify dipswitch 8 is "on"
Green
Flash Code 2
Future Use N/A N/A N/A
Green
Flash Code 3
Short Cycling
Run time of less than 1
minute; number of short
cycles exceeds 48 in 24
hours
< 48 short cycles in
24 hours
1) Check system charge and
pressure control setting
2) Adjust set-point of
temperature controller
3) Install anti-short cycling
control
Green
Flash Code 4
Not used with this
compressor family
N/A N/A N/A
Green
Flash Code 5
Future Use N/A N/A N/A
Table 7 – Protector Specications
Module P/N 071-0660-01 071-0660-00 071-0686-01 071-0686-00 571-0065-05 571-0064-06
Compressor Motor Code TW TW TW TW TE TE
Type Kriwan Kriwan
Kriwan
Diagnose*
Kriwan
Diagnose*
CoreSense CoreSense
T1-T2 Voltage (AC) 24 120/240 24 120/240 24 120/240
Power Consumption (VA) 3 3 3 3 5 5
M1-M2 Contact Rating (A) 2.5 2.5 2.5 2.5 2.5 2.5
M1-M2 Minimum Current (A) > 0.02 > 0.02 > 0.02 > 0.02 N/A N/A
M1-M2 Maximum Voltage 240 240 240 240 240 240
Trip Point (Ω) >4.5KΩ >4.5KΩ >4.5KΩ >4.5KΩ
>4.5KΩ
(motor)
>4.5KΩ
(motor)
Reset Point (Ω) <2.75KΩ <2.75KΩ <2.75KΩ <2.75KΩ
<2.75KΩ
(motor)
<2.75KΩ
(motor)
Reset Time 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes 30 minutes
Features Motor Protection
Motor Protection, Phase
Protection, Communications
* Diagnose features not supported

Table of Contents

Other manuals for Emerson Copeland Scroll ZR KC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Copeland Scroll ZR KC Series and is the answer not in the manual?

Emerson Copeland Scroll ZR KC Series Specifications

General IconGeneral
BrandEmerson
ModelCopeland Scroll ZR KC Series
CategoryAir Compressor
LanguageEnglish

Related product manuals